The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

GE 14294 (ZW3005) In-Wall Dimmer Switch

This describes the Z-Wave device GE 14294 (ZW3005), manufactured by Jasco Products with the thing type UID of ge_ge14294_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

GE 14294 (ZW3005) product image

The GE 14294 (ZW3005) supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the GE 14294 (ZW3005) -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the GE 14294 (ZW3005). Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Night Light Defines the behavior of the blue LED. Default is on when switch is off.
4 Invert Switch Invert the ON/OFF Switch State.
5 Ignore Start-Level (Receiving) This dimmer will start dimming from its current level.
7 On/Off Command Dim Step Indicates how many levels the dimmer will change per step.
8 On/Off Command Dim Rate This sets how often the dim level will change.
9 Local Control Dim Step How many levels the dimmer will change for each step.
10 Local Control Dim Rate This sets how often the dim level will change.
11 ALL ON/ALL OFF Dim Step How many levels the dimmer will change per step.
12 ALL ON/ALL OFF Dim Rate This sets how often the dim level will change.
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Night Light

Defines the behavior of the blue LED. Default is on when switch is off.

The following option values may be configured -:

Value Description
0 LED on when switch is OFF
1 LED on when switch is ON
2 LED always off

The manufacturer defined default value is 0 (LED on when switch is OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Invert the ON/OFF Switch State.

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Ignore Start-Level (Receiving)

This dimmer will start dimming from its current level.

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 7: On/Off Command Dim Step

Indicates how many levels the dimmer will change per step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: On/Off Command Dim Rate

This sets how often the dim level will change.

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Local Control Dim Step

How many levels the dimmer will change for each step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Local Control Dim Rate

This sets how often the dim level will change.

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: ALL ON/ALL OFF Dim Step

How many levels the dimmer will change per step.

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: ALL ON/ALL OFF Dim Rate

This sets how often the dim level will change.

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The GE 14294 (ZW3005) supports 2 association groups.

Group 1: Z-Wave Plus Lifeline

Z-Wave Plus Lifeline This group supports 1 nodes.

Group 3: Scene group

This group gets notifications of double taps via basic set This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_CRC_16_ENCAP_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.