26933/ZW3008 In-Wall Smart Motion Dimmer

This describes the Z-Wave device 26933/ZW3008, manufactured by Jasco Products with the thing type UID of ge_26933_00_000.

In-Wall Smart Motion Dimmer

Channels

The following table summarises the channels available for the 26933/ZW3008 In-Wall Smart Motion Dimmer.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number   Number
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Switch 1 switch_dimmer1 switch_dimmer DimmableLight Dimmer
Alarm (burglar) 2 alarm_burglar2 alarm_burglar Door Switch

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Switch 1

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the 26933/ZW3008 In-Wall Smart Motion Dimmer. Detailed information on each parameter can be found below.

Parameter Description
1: Timeout Duration Amount of time the light stays on after motion stops
2: Dim Level Change brightness of associated light bulb(s)
3: Operation Mode Sets Manual, Vacancy (manual on, auto off), Occupancy (auto on, auto off)
4: Association Mode Enable/Disable Association Mode
5: Invert Switch In a 3-way configuration, invert the connected Add-On Switch buttons
6: Motion Sensor Enable/Disable Motion Sensor
7: Z-Wave Command Dim Step Indicates how many levels the dimmer will change for each dimming step.
8: Z-Wave Command Dim Rate How often the dim level will change in 10 millisecond resolution.
9: Local Control Dim Step Indicates how many levels the dimmer will change for each dimming step.
10: Local Control Dim Rate How often the dim level will change in 10 millisecond resolution.
11: ALL ON/ALL OFF Dim Step Indicates how many levels the dimmer will change for each dimming step.
12: ALL ON/ALL OFF Dim Rate How often the dim level will change in 10 millisecond resolution.
13: Motion Sensor Sensitivity Amount of motion required to turn on the light
14: Light Sensing Enable/Disable whether motion sensor only turns light on if room is dark
15: Reset Cycle Reset Cycle
16: Switch Mode  
17: Switch Level Switch Level
18: Dim Up Rate  
19: Exclusion mode  
1: Z-Wave Plus Lifeline Z-Wave Plus Lifeline, Multi-Level Report
2: Basic Set Local Load Supports Basic Set and is controlled with the local load
3: Basic Set Buttons Supports Basic Set and is controlled by pressing the On or Off buttons

1: Timeout Duration

Amount of time the light stays on after motion stops

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 5
Options Test (5s) (0)      
  1 minute (1)      
  5 minutes (5)      
  15 minutes (15)      
  30 minutes (30)      
  Disable timeout (255)      

2: Dim Level

Change brightness of associated light bulb(s)

Overview

Valid values are 0-99 or 255 for last dimming level

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 255
Default Value 255

3: Operation Mode

Sets Manual, Vacancy (manual on, auto off), Occupancy (auto on, auto off)

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 3
Options Manual (1)      
  Vacancy (2)      
  Occupancy (3)      

4: Association Mode

Enable/Disable Association Mode

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Enabled (1)      

5: Invert Switch

In a 3-way configuration, invert the connected Add-On Switch buttons

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

6: Motion Sensor

Enable/Disable Motion Sensor

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Enabled (1)      

7: Z-Wave Command Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Overview

1=Default
2-99=Steps/Levels

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 99
Default Value 1

8: Z-Wave Command Dim Rate

How often the dim level will change in 10 millisecond resolution.

Overview

For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. The default is 3 (30 ms).

Property Value
Configuration ID config_8_2
Data Type INTEGER
Range 1 to 255
Default Value 3

9: Local Control Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Overview

1=Default
2-99=Steps/Levels

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 1 to 99
Default Value 1

10: Local Control Dim Rate

How often the dim level will change in 10 millisecond resolution.

Overview

For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. The default is 3 (30 ms).

Property Value
Configuration ID config_10_2
Data Type INTEGER
Range 1 to 255
Default Value 3

11: ALL ON/ALL OFF Dim Step

Indicates how many levels the dimmer will change for each dimming step.

Overview

1=Default
2=99=Steps/Levels

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 1 to 99
Default Value 1

12: ALL ON/ALL OFF Dim Rate

How often the dim level will change in 10 millisecond resolution.

Overview

For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change. The default is 3 (30 ms).

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 1 to 255
Default Value 3

13: Motion Sensor Sensitivity

Amount of motion required to turn on the light

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 2
Options High (1)      
  Medium (2)      
  Low (3)      

14: Light Sensing

Enable/Disable whether motion sensor only turns light on if room is dark

Overview

Light Sensing does not apply in Manual or Vacancy modes

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

15: Reset Cycle

Reset Cycle

Overview

0=disable
1=10 seconds
2=20 seconds
3=30 seconds
4=45 seconds
5 to 109 = 15 second intervals, starting at 60 seconds
110=27 minutes 15 seconds

Property Value
Configuration ID config_15_2
Data Type INTEGER
Range 0 to 110
Default Value 2

16: Switch Mode

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (1)      

17: Switch Level

Switch Level

Overview

0=disabled (default)
1-99=Brightness Level

Property Value
Configuration ID config_17_1
Data Type INTEGER
Range 0 to 99
Default Value 0

18: Dim Up Rate

Property Value      
Configuration ID config_18_1      
Data Type INTEGER   Default Value 0
Options Dim up the light to the default level quickly (Default) (0)      
  Dim up the light to the default level slowly (1)      

19: Exclusion mode

Property Value      
Configuration ID config_19_1      
Data Type INTEGER   Default Value 0
Options Press and release any button on the switch (Default) (0)      
  Press and release “X” btn and repeat for “ON“ btn (1)      

1: Z-Wave Plus Lifeline

Z-Wave Plus Lifeline, Multi-Level Report

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic Set Local Load

Supports Basic Set and is controlled with the local load

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Basic Set Buttons

Supports Basic Set and is controlled by pressing the On or Off buttons

Property Value
Configuration ID group_3
Data Type TEXT
Range to