GE 14295 In-Wall Dimmer Switch

This describes the Z-Wave device GE 14295, manufactured by Jasco Products with the thing type UID of ge_ge14295_00_000.

In-Wall Dimmer Switch

Inclusion Information

  1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network.

  2. Once the controller is ready to include your device, press and release the top or bottom of the wireless smart dimmer(rocker) to include it in the network. 

Exclusion Information

  1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.

  2. Once the controller is ready to Exclude your device, press and release the top or bottom of the wireless smart dimmer (rocker) to exclude it from the network. 

Channels

The following table summarises the channels available for the GE 14295 In-Wall Dimmer Switch.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number   Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the GE 14295 In-Wall Dimmer Switch. Detailed information on each parameter can be found below.

Parameter Description
4: Invert Switch Invert the ON/OFF Switch State.
7: Dim Rate Adjustments Number of steps or levels
8: Dim Rate Adjustments Timing of steps or levels
9: Dim Rate Adjustments Number of steps or levels
10: Dim Rate Adjustments Timing of steps
11: Dim Rate Adjustments Number of steps or levels
12: Dim Rate Adjustments Timing of steps or levels
1: Association Group 1 Z-Wave Plus Lifeline, Multilevel Switch Report
2: Association Group 2 Supports Basic Set and is controlled with the local load
3: Association Group 3 Supports Basic Set and is controlled by double pressing the On or Off button

4: Invert Switch

Invert the ON/OFF Switch State.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options (Default) No (0)      
  Yes (1)      

7: Dim Rate Adjustments

Number of steps or levels

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 99
Default Value 1

8: Dim Rate Adjustments

Timing of steps or levels

Property Value
Configuration ID config_8_2
Data Type INTEGER
Range 1 to 255
Default Value 3

9: Dim Rate Adjustments

Number of steps or levels

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 1 to 99
Default Value 1

10: Dim Rate Adjustments

Timing of steps

Property Value
Configuration ID config_10_2
Data Type INTEGER
Range 1 to 255
Default Value 3

11: Dim Rate Adjustments

Number of steps or levels

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 1 to 99
Default Value 1

12: Dim Rate Adjustments

Timing of steps or levels

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 1 to 255
Default Value 3

1: Association Group 1

Z-Wave Plus Lifeline, Multilevel Switch Report

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Association Group 2

Supports Basic Set and is controlled with the local load

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Association Group 3

Supports Basic Set and is controlled by double pressing the On or Off button

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.