32563 Smart Door Sensor

This describes the Z-Wave device 32563, manufactured by Jasco Products with the thing type UID of ge_smartdoorsensor_00_000.

Smart Door Sensor

Inclusion Information

  1. Follow the instructions for your Z-Wave certified controller to include the device to the Z-Wave network.
  2. Once the controller is ready to include your Hinge Pin Smart Door Sensor press and release the manual/program button on the smart switch to include it in the network.

Exclusion Information

  1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. 
  2. Once the controller is ready to exclude your device, press and release the manual/program button on the Hinge Pin Smart Door Sensor to exclude it from the network.

You may wish to reset all of your Hinge Pin Smart Door Sensor’s settings to their factory defaults. To do this, press the program button 10 times within 6 seconds. If your Door Sensor has been successfully reset, its LED light will blink for 3 seconds. This should only be used in the event your network’s primary controller is missing or otherwise inoperable.

Wakeup Information

  1. Press and hold the Z-wave Button for 6 seconds. It will be wake up and send “Wake Up Notification CC “ to HUB. 
  2. It will sleep after timeout for 10 seconds, or sleep right away when received the “Wake Up No More Information CC”. 

Channels

The following table summarises the channels available for the 32563 Smart Door Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (access) alarm_access alarm_access Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the 32563 Smart Door Sensor. Detailed information on each parameter can be found below.

Parameter Description
20: Report Method Change Open/Close Report Method
1: 1 Z-Wave Plus Lifeline
2: 2 For Control
3: 3 For Control

20: Report Method

Change Open/Close Report Method

Overview
  1. Notification (Default)
  2. Basic Set
  3. Basic Report
Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 1 to 3
Default Value 1

1: 1

Z-Wave Plus Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: 2

For Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: 3

For Control

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.