ZW3102 Jasco Energy Monitoring Lamp Dimmer

This describes the Z-Wave device ZW3102, manufactured by Jasco Products with the thing type UID of ge_zw3102_00_000.

Jasco Energy Monitoring Lamp Dimmer

Channels

The following table summarises the channels available for the ZW3102 Jasco Energy Monitoring Lamp Dimmer.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW3102 Jasco Energy Monitoring Lamp Dimmer. Detailed information on each parameter can be found below.

Parameter Description
5: Ignore start level Ignore start level when receiving zwave dim commands
7: Zwave Dim Steps Number of dim steps when receving a zwave dim command
8: Zwave Step Timing Timing of dim steps when receving a zwave dim command
9: Rocker Dim Steps Number of dim steps when pressing the rocker
10: Rocker Step Timing Timing of dim steps when pressing the rocker
11: Zwave Dim Steps - All Command Number of dim steps when receving a zwave All-On or All-off command
12: Zwave Step Timing - All Command Timing of dim steps when receving a zwave All-On or All-Off command

5: Ignore start level

Ignore start level when receiving zwave dim commands

Overview

Every “Dim” command from your remote controller includes a start level embedded in it.  This device can be set to ignore the start level that is part of the dim command

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Obey commend start level (0)      
  Ignore commend start level (1)      

7: Zwave Dim Steps

Number of dim steps when receving a zwave dim command

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 99
Default Value 1

8: Zwave Step Timing

Timing of dim steps when receving a zwave dim command

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 1 to 255
Default Value 3

9: Rocker Dim Steps

Number of dim steps when pressing the rocker

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 1 to 99
Default Value 1

10: Rocker Step Timing

Timing of dim steps when pressing the rocker

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 1 to 255
Default Value 3

11: Zwave Dim Steps - All Command

Number of dim steps when receving a zwave All-On or All-off command

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 1 to 99
Default Value 1

12: Zwave Step Timing - All Command

Timing of dim steps when receving a zwave All-On or All-Off command

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 1 to 255
Default Value 3

Did you spot an error in the above definition or want to improve the content? You can edit the database here.