ZW4002 In-Wall Smart Fan Control

This describes the Z-Wave device ZW4002, manufactured by Jasco Products with the thing type UID of ge_zw4002_00_000.

In-Wall Smart Fan Control

Overview

Basic Operation

Note: Before starting, fan must be set to ‘HIGH’ position using pull chain. The connected fan can then be turned ON/OFF and adjust speed levels in two ways:

  1. Manually from the front panel rocker of the In-wall Fan Control
  2. Remotely with a Z-Wave controller

Manual Control

To turn the connected fan ON: Press and release the top of the rocker. Note: Fan will return to last speed setting of Fan Control. Default setting – HIGH.

To turn the fan OFF: Press and release the bottom of the rocker.

Adjust fan speed

To decrease fan speed: Press and hold lower rocker.

To increase fan speed: Press and hold upper rocker.

The LED indicator confirms fan speed settings by flashing patterns

  • LOW – LED will blink every 2 seconds for 10 seconds
  • MEDIUM – LED will blink every second for 10 seconds
  • HIGH – LED will blink every half second for 10 seconds

Inclusion Information

Once the controller is ready to include your device, press and release the top or bottom of the smart fan control switch (rocker) to include it in the network.

Exclusion Information

Tap up or down

Wakeup Information

Tap up or down

Channels

The following table summarises the channels available for the ZW4002 In-Wall Smart Fan Control.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZW4002 In-Wall Smart Fan Control. Detailed information on each parameter can be found below.

Parameter Description
3: Night Light Defines the behavior of the blue LED
4: Invert Switch Invert the ON/OFF Switch State
1: Lifeline Z-Wave Plus Lifeline
2: Controlled with local load Supports Basic Set and is controlled with the local load
3: Double Tap Supports Basic Set and is controlled by double pressing the On or Off button

3: Night Light

Defines the behavior of the blue LED

Overview

Default is Night Light mode where LED is on when switch is off.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options LED on when switch is OFF (0)      
  LED on when switch is ON (1)      
  LED always off (2)      

4: Invert Switch

Invert the ON/OFF Switch State

Overview

Setting this parameter to Yes will change the top of the switch to OFF and the bottom to ON.  Note: If you invert the switches and also install the product upside down, the load will now be control.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

1: Lifeline

Z-Wave Plus Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Controlled with local load

Supports Basic Set and is controlled with the local load

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Double Tap

Supports Basic Set and is controlled by double pressing the On or Off button

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.