GWPN1 Single-socket PowerNode

This describes the Z-Wave device GWPN1, manufactured by GreenWave Reality Inc. with the thing type UID of greenwave_gwpn1_03_000.

Single-socket PowerNode

Overview

This Configuration is for the 1 plug version of the PowerNode.

It should work for both NS210 and NS310 devices.

Inclusion Information

On the PowerNode, press and hold the Sync button for approximately one second until the activity indicator displays a clockwise rotating pattern. This indicates the PowerNode is attempting inclusion. During this process, verify that the Gateway activity indicator still displays a clockwise rotating pattern.

After a few seconds, the rotating pattern on both the PowerNode and the Gateway stops. All bars turn green forming a circle for several seconds. This indicates a successful inclusion.

If all bars on the activity indicator start flashing instead of forming a solid circle, then the PowerNode inclusion process has failed, and you must start the sync process again. If syncing continually fails even though the PowerNode is close to the Gateway, then it may be an indication of a hardware fault, and the PowerNode might need replacing.

Exclusion Information

On the PowerNode, press and hold the Sync button for approximately one second until the PowerNode activity indicator begins to display a counter-clockwise rotating pattern. The PowerNode is attempting exclusion.

Channels

The following table summarises the channels available for the GWPN1 Single-socket PowerNode.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Reset total power consumption meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the GWPN1 Single-socket PowerNode. Detailed information on each parameter can be found below.

Parameter Description
0: Min. variation of load current Minimum variation in load current before a message is sent.
1: No communication light Minutes after which the device will flash if controller communicate is lost
2: Wheel position Wheel position on the GreenWave device (read-only)
3: Power-on state Default state after power loss
4: LED for network error If the LED should indicate a network error by flashing or not
1: Wheel position change  
2: Current leakage on relay  
3: Power level change  
4: Over-current detection  

0: Min. variation of load current

Minimum variation in load current before a message is sent.

Overview

 Value in percent (30 => 30%)

Property Value
Configuration ID config_0_1
Data Type INTEGER
Range 0 to 100
Default Value 0

1: No communication light

Minutes after which the device will flash if controller communicate is lost

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 2

2: Wheel position

Wheel position on the GreenWave device (read-only)

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Black (128)      
  Green (129)      
  Dark Blue (130)      
  Red (131)      
  Yellow (132)      
  Purple (133)      
  Orange (134)      
  Light Blue (135)      
  Pink (136)      
  Locked (137)      

3: Power-on state

Default state after power loss

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 2
Options All OFF (0)      
  Remember last state (1)      
  All ON (2)      

4: LED for network error

If the LED should indicate a network error by flashing or not

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options Disable the LED for network error (0)      
  Enable the LED for network error (1)      

1: Wheel position change

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Current leakage on relay

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Power level change

Overview

The new power reading is sent if the delta of the change is greater than the defined minimum variation.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Over-current detection

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.