GWPN5 Multi-socket PowerNode (5-plug)

This describes the Z-Wave device GWPN5, manufactured by GreenWave Reality Inc. with the thing type UID of greenwave_gwpn5_00_000.

Multi-socket PowerNode (5-plug)

Overview

This Configuration is for the 6 plug version of the PowerNode.

Inclusion Information

On the PowerNode, press and hold the sync button for approximately one second until the activity indicator displays a clockwise rotating pattern. This indicates the PowerNode is attempting inclusion. During this process, verify that the Gateway activity indicator still displays a clockwise rotating pattern.

After a few seconds, the rotating pattern on both the PowerNode and the Gateway stops. All bars turn green forming a circle for several seconds. This indicates a successful inclusion.

If all bars on the activity indicator start flashing instead of forming a solid circle, then the PowerNode inclusion process has failed, and you must start the sync process again. If syncing continually fails even though the PowerNode is close to the Gateway, then it may be an indication of a hardware fault, and the PowerNode might need replacing.

Exclusion Information

On the PowerNode, press and hold the Sync button for approximately one second until the PowerNode activity indicator begins to display a counter-clockwise rotating pattern. The PowerNode is attempting exclusion.

Channels

The following table summarises the channels available for the GWPN5 Multi-socket PowerNode (5-plug).

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Alarm alarm_general alarm_general Door Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Switch 3 switch_binary3 switch_binary Switch Switch
Electric meter (watts) 3 meter_watts3 meter_watts Energy Number
Electric meter (kWh) 3 meter_kwh3 meter_kwh Energy Number
Switch 4 switch_binary4 switch_binary Switch Switch
Electric meter (watts) 4 meter_watts4 meter_watts Energy Number
Electric meter (kWh) 4 meter_kwh4 meter_kwh Energy Number
Switch 5 switch_binary5 switch_binary Switch Switch
Electric meter (watts) 5 meter_watts5 meter_watts Energy Number
Electric meter (kWh) 5 meter_kwh5 meter_kwh Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the GWPN5 Multi-socket PowerNode (5-plug). Detailed information on each parameter can be found below.

Parameter Description
0: Min. variation of load current Minimum variation in load current before a message is sent.
1: No communication light Minutes after which the device will flash if controller communicate is lost
2: Wheel position Wheel position on the GreenWave device (read-only)
3: Power-on state Default state after power loss
4: LED for network error If the LED should indicate a network error by flashing or not
1: Wheel position change  
2: Current leakage on relay  
3: Power level change The new power reading is sent if the delta of the change is greater than the defined minim…
4: Over-current detection  

0: Min. variation of load current

Minimum variation in load current before a message is sent.

Overview

Value in percent (30 => 30%)

Property Value
Configuration ID config_0_1
Data Type INTEGER
Range 0 to 100
Default Value 10

1: No communication light

Minutes after which the device will flash if controller communicate is lost

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 2

2: Wheel position

Wheel position on the GreenWave device (read-only)

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Black (128)      
  Green (129)      
  Dark Blue (130)      
  Red (131)      
  Yellow (132)      
  Purple (133)      
  Orange (134)      
  Light Blue (135)      
  Pink (136)      
  Locked (137)      

3: Power-on state

Default state after power loss

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 2
Options All OFF (0)      
  Remember last state (1)      
  All ON (2)      

4: LED for network error

If the LED should indicate a network error by flashing or not

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options Disable the LED for network error (0)      
  Enable the LED for network error (1)      

1: Wheel position change

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Current leakage on relay

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Power level change

The new power reading is sent if the delta of the change is greater than the defined minimum variation

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Over-current detection

Property Value
Configuration ID group_4
Data Type TEXT
Range to