HKZW_MS02 Motion Sensor

This describes the Z-Wave device HKZW_MS02, manufactured by Hank with the thing type UID of hank_hkzwms02_00_000.

The device is in the category of Sensor, defining Device used to measure something.

The HKZW_MS02 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the HKZW_MS02 -:

Channel Channel Id Category Item Type
Alarm (burglar) alarm_burglar Door Switch
Battery Level battery-level Battery Number

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the HKZW_MS02. Detailed information on each parameter can be found in the sections below.

Param Name Description
12 Motion Sensor`s Sensitivity The higher the value,the more sensitive the PIR sensor
14 Enable/Disable Basic Set Command The motion Sensor can reverse its value of BASIC SET when motion is triggered
15 value of basic set command assigned to send Basic Set Command
17 enable/disable shock alarm  
32 Level of low battery Define a battery level ad the “low battery”
  Wakeup Interval Sets the interval at which the device will accept commands from the controller
  Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 12: Motion Sensor`s Sensitivity

The higher the value,the more sensitive the PIR sensor

The following option values may be configured -:

Value Description
0 0
1 1
2 2

The manufacturer defined default value is 8.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 14: Enable/Disable Basic Set Command

The motion Sensor can reverse its value of BASIC SET when motion is triggered

The following option values may be configured -:

Value Description
0 Disable
1 enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: value of basic set command

assigned to send Basic Set Command

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 17: enable/disable shock alarm

The following option values may be configured -:

Value Description
0 Disable
1 enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 32: Level of low battery

Define a battery level ad the “low battery”

Values in the range 10 to 50 may be set.

The manufacturer defined default value is 20.

This parameter has the configuration ID config_32_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The HKZW_MS02 supports 2 association groups.

Group 1: report the motion detection and battery level

This group supports 5 nodes.

Group 2: assigned to send BASIC SET command

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V5 Linked to BASIC
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_WAKE_UP_V2  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.