HKZW_FLD01 Flood Sensor FLD01

This describes the Z-Wave device HKZW_FLD01, manufactured by Hank with the thing type UID of hank_hkzwfld01_00_000.

Flood Sensor FLD01

Channels

The following table summarises the channels available for the HKZW_FLD01 Flood Sensor FLD01.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Alarm (heat) alarm_heat alarm_heat   Switch
Alarm (flood) alarm_flood alarm_flood Door Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the HKZW_FLD01 Flood Sensor FLD01. Detailed information on each parameter can be found below.

Parameter Description
14: Enable/Disable Basic Set Command The flood sensor can send BASIC SET command to nodes associated
15: value of the Basic Set The flood sensor can send BASIC SET command to nodes associated
17: Flooding Alarm Enable/Disable flooding alarm
18: Shock Alarm Enable/Disable shock alarm
19: High Temperature Alarm Enable/Disable high temperature alarm
20: Set the high temperature alarm trigger value Available setting(US):-67°c to -257°c
21: Low Temperature Alarm Enable/Disable low temperature alarm
22: Set the low temperature alarm trigger value Available setting(US):-67°c to -257°c
24: Blinking LED Enable/Disable blinking LED when alarm being triggerd
32: Level of low battery This parameter defines a battery level as the “low bettery”
1: Report report the flooding detection,shock detection and the battert level
2: Send Command Group 2 is assigned to send BASIC SET command

14: Enable/Disable Basic Set Command

The flood sensor can send BASIC SET command to nodes associated

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

15: value of the Basic Set

The flood sensor can send BASIC SET command to nodes associated

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

17: Flooding Alarm

Enable/Disable flooding alarm

Property Value      
Configuration ID config_17_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

18: Shock Alarm

Enable/Disable shock alarm

Property Value      
Configuration ID config_18_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

19: High Temperature Alarm

Enable/Disable high temperature alarm

Property Value      
Configuration ID config_19_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

20: Set the high temperature alarm trigger value

Available setting(US):-67°c to -257°c

Property Value
Configuration ID config_20_2
Data Type INTEGER
Range -670 to 2570
Default Value 1040

21: Low Temperature Alarm

Enable/Disable low temperature alarm

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

22: Set the low temperature alarm trigger value

Available setting(US):-67°c to -257°c

Property Value
Configuration ID config_22_2
Data Type INTEGER
Range -670 to 2570
Default Value 0

24: Blinking LED

Enable/Disable blinking LED when alarm being triggerd

Property Value      
Configuration ID config_24_1      
Data Type INTEGER   Default Value 1
Options Disable (0)      
  Enable (1)      

32: Level of low battery

This parameter defines a battery level as the “low bettery”

Property Value
Configuration ID config_32_1
Data Type INTEGER
Range 10 to 50
Default Value 20

1: Report

report the flooding detection,shock detection and the battert level

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Send Command

Group 2 is assigned to send BASIC SET command

Property Value
Configuration ID group_2
Data Type TEXT
Range to