HKZW_MS01 Multisensor

This describes the Z-Wave device HKZW_MS01, manufactured by Hank with the thing type UID of hank_hkzwms01_00_000.

Multisensor

Channels

The following table summarises the channels available for the HKZW_MS01 Multisensor.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the HKZW_MS01 Multisensor. Detailed information on each parameter can be found below.

Parameter Description
12: Motion Sensor`s Sensitivity The higher the value,the more sensitive the PIR sensor
14: Enable/Disable Basic Set Command The motion Sensor can reverse its value of BASIC SET when motion is triggered
15: value of basic set command  
1: Lifeline Reports the motion detection and battery
2: Basic Set assigned to send Basic Set Command

12: Motion Sensor`s Sensitivity

The higher the value,the more sensitive the PIR sensor

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 8
Options 1 (1)      
  2 (2)      
  3 (3)      
  4 (4)      
  5 (5)      
  6 (6)      
  7 (7)      
  8 (8)      

14: Enable/Disable Basic Set Command

The motion Sensor can reverse its value of BASIC SET when motion is triggered

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 0
Options Disable (0)      
  Enable (1)      

15: value of basic set command

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options send off (0)      
  send on (1)      

1: Lifeline

Reports the motion detection and battery

Overview

Reports the motion detection and battery

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic Set

assigned to send Basic Set Command

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.