HKZW_MS01 Multisensor
This describes the Z-Wave device HKZW_MS01, manufactured by Hank with the thing type UID of hank_hkzwms01_00_000
.
Multisensor
Channels
The following table summarises the channels available for the HKZW_MS01 Multisensor.
Channel | Channel Id | Channel Type UID | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number |
Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number |
Sensor (luminance) | sensor_luminance | sensor_luminance | Temperature | Number |
Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch |
battery-level | system.battery-level |
Sensor (temperature)
Scale
Select the scale for temperature readings
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_scale | |||
Data Type | TEXT | Default Value | 0 | |
Options | Celsius (0) | |||
Fahrenheit (1) |
Device Configuration
The following table provides a summary of the configuration parameters available in the HKZW_MS01 Multisensor. Detailed information on each parameter can be found below.
Parameter | Description |
---|---|
12: Motion Sensor`s Sensitivity | The higher the value,the more sensitive the PIR sensor |
14: Enable/Disable Basic Set Command | The motion Sensor can reverse its value of BASIC SET when motion is triggered |
15: value of basic set command | |
1: Lifeline | Reports the motion detection and battery |
2: Basic Set | assigned to send Basic Set Command |
12: Motion Sensor`s Sensitivity
The higher the value,the more sensitive the PIR sensor
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_12_1 | |||
Data Type | INTEGER | Default Value | 8 | |
Options | 1 (1) | |||
2 (2) | ||||
3 (3) | ||||
4 (4) | ||||
5 (5) | ||||
6 (6) | ||||
7 (7) | ||||
8 (8) |
14: Enable/Disable Basic Set Command
The motion Sensor can reverse its value of BASIC SET when motion is triggered
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_14_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Disable (0) | |||
Enable (1) |
15: value of basic set command
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_15_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | send off (0) | |||
send on (1) |
1: Lifeline
Reports the motion detection and battery
Overview
Reports the motion detection and battery
Property | Value |
---|---|
Configuration ID | group_1 |
Data Type | TEXT |
Range | to |
2: Basic Set
assigned to send Basic Set Command
Property | Value |
---|---|
Configuration ID | group_2 |
Data Type | TEXT |
Range | to |