HKZW-SO01 Smart Plug with two USB ports

This describes the Z-Wave device HKZW-SO01, manufactured by Hank with the thing type UID of hank_hkzws001_00_000.

Smart Plug with two USB ports

Overview

Hank Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (On/Off) of any plug-in tool. It can report wattage consumption or kWh energy usage. Smart Plug is also a security Z-Wave device and supports Over The Air (OTA) feature for the product’s firmware upgrade.

Based on the Z-Wave Plus specification.

Features List:

  1. Supports 1xAC output and 2xUSB outputs;
  2. AC output switch on/off by manual or Z-Wave command;
  3. LED indicates the working status;
  4. Z-Wave plus compatible (500 serials Product);
  5. Supporting power meter;
  6. Supporting repeater role
  7. Supporting firmware OTA

Inclusion Information

Manual Z-Wave network inclusion:

(1) Connect the power supply.

(2) Set the Z-Wave network main controller into learning mode (see Z-Wave network controller operating manual).

(3) Triple click the Z-button

(4) Smart Plug should be recognized and included into the Z-Wave network.

TIP:

If the LED indicator not blinking when inserting a Plug into a socket, it means the plug was already added in other existing network.

Exclusion Information

REMOVING FROM Z-WAVE NETWORK

To remove Smart Plug from the Z-Wave network:

(1) Insert the Plug into a socket,

(2) Set the Z-Wave network controller into the exclusion mode (see Z-Wave controller operating manual)

(3) Triple click the Z button.

Channels

The following table summarises the channels available for the HKZW-SO01 Smart Plug with two USB ports.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number   Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the HKZW-SO01 Smart Plug with two USB ports. Detailed information on each parameter can be found below.

Parameter Description
20: Overload Protection If current exceeds 16.5A over 5 seconds, relay will turn off.
21: Device Status after Power Failure Define how the plug reacts after power failure
24: Notifcation on Load Change Smart Plug can send notifications to association device load state changes.
27: Indicator Modes LED in the device will indicate the state of load
151: Threshold of power report Power Threshold at which to send meter report
152: Percentage Threshold of Power Report Percentage Threshold at which to send meter report
171: Power Report Frequency The interval of sending power report to association device (Group Lifeline).
172: Energy Report Frequency The interval of sending energy report to association device (Group Lifeline).
173: Voltage Report Frequency The interval of sending voltage report to association device (Group Lifeline)
174: Electricity Report Frequency Interval for sending electricity report.
1: Basic Report Sends Basic Report at On/Off event

20: Overload Protection

If current exceeds 16.5A over 5 seconds, relay will turn off.

Overview

If current exceeds 16.5A over 5 seconds, relay will turn off.

0 - The function is disabled

1 - The function is enabled.

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 1
Default Value 1

21: Device Status after Power Failure

Define how the plug reacts after power failure

Overview

Define how the plug reacts after power failure:

0 - Smart Plug returns to previous state after a power failure.

1 - Smart Plug does not memorize its state after a powerfailure.

Connected device will be on after the power supply is reconnected.

2 - Smart Plug does not memorize its state after a power failure.

Connected device will be off after the power supply is reconnected.

Property Value
Configuration ID config_21_1
Data Type INTEGER
Range 0 to 2
Default Value 0

24: Notifcation on Load Change

Smart Plug can send notifications to association device load state changes.

Overview

Smart Plug can send notifications to association device load state changes.

0 -Disabled.

1 - Basic report.

2 - Basic report only when Load condition not changed by Z-WAVE Command.

Property Value
Configuration ID config_24_1
Data Type INTEGER
Range 0 to 2
Default Value 1

27: Indicator Modes

LED in the device will indicate the state of load

Overview

After smart plug is included into a Z-Wave network, the LED in the device will indicate the state of load.

0 - The LED will follow the status (on/off) of its load.

1 - When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is not any switch action.

Property Value
Configuration ID config_27_1
Data Type INTEGER
Range 0 to 1
Default Value 0

151: Threshold of power report

Power Threshold at which to send meter report

Overview

Power threshold to be interpreted, when the change value of load power exceeds the setting threshold, the smart plug will send meter report to association device (Group Lifeline).

Available settings: 0 - 65535 (0 - 65535W)

0 - The function is disabled.

Default setting: 50 (50W)

Property Value
Configuration ID config_151_2
Data Type INTEGER
Range 0 to 65535
Default Value 50

152: Percentage Threshold of Power Report

Percentage Threshold at which to send meter report

Overview

Power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart plug will send meter report to association device (Group Lifeline).

Available settings: 0 - 255 (0 - 255%)

0 - The function is disabled.

Default setting: 10 (10%)

Property Value
Configuration ID config_152_1
Data Type INTEGER
Range 0 to 255
Default Value 10

171: Power Report Frequency

The interval of sending power report to association device (Group Lifeline).

Overview

The interval of sending power report to association device (Group Lifeline).

Available settings: 5- 2678400 (5 - 2678400 seconds)

0 -The function is disabled.

Default setting: 30 (30 seconds).

Property Value
Configuration ID config_171_4
Data Type INTEGER
Range 5 to 2678400
Default Value 30

172: Energy Report Frequency

The interval of sending energy report to association device (Group Lifeline).

Overview

The interval of sending energy report to association device (Group Lifeline).

Available settings: 5- 2678400 (5 - 2678400 seconds)

0 -The function is disabled.

Default setting: 300 (300 seconds).

Property Value
Configuration ID config_172_4
Data Type INTEGER
Range 5 to 2678400
Default Value 300

173: Voltage Report Frequency

The interval of sending voltage report to association device (Group Lifeline)

Overview

The interval of sending voltage report to association device (Group Lifeline)

Available settings: 5- 2678400 (5 - 2678400 seconds)

0 -The function is disabled.

Default setting: 0 (disabled).

Property Value
Configuration ID config_173_4
Data Type INTEGER
Range 0 to 2678400
Default Value 0

174: Electricity Report Frequency

Interval for sending electricity report.

Overview

The interval of sending electricity report to association device (Group Lifeline).

Available settings: 5- 2678400 (5 - 2678400 seconds)

0 -The function is disabled.

Default setting: 0 (disabled).

Property Value
Configuration ID config_174_4
Data Type INTEGER
Range 0 to 2678400
Default Value 0

1: Basic Report

Sends Basic Report at On/Off event

Overview

Association command class allows Smart Plug to communicate with other Z-Wave devices directly, such as sending BASIC REPORT whenever the smart plug is turn on or off.

Smart Plug supports 1 association grouping.

The max number of associated nodes is 5.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.