HKZW-SO05 Smart Plug

This describes the Z-Wave device HKZW-SO05, manufactured by Hank with the thing type UID of hank_so05_00_000.

Smart Plug

Overview

Smart plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage. Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade.

HKZW-SO05 is a Smart Plug based on Z-Wave plus specification

The features list:

1) Supports 1xAC output and 2xUSB outputs;

2) AC output switch on/off by manual or Z-Wave command;

3) RGB LED indicates the Z-Wave network range;

4) RGB LED indicates the load power;

5) Z-Wave plus compatible (500 serials product);

6) supporting power meter;

7) supporting repeater role;

Supporting firmware OTA;

Inclusion Information

Automatic Z-Wave network inclusion:

1) Set the Z-Wave network main controller into inclusion mode.

2) Insert the Plug into a socket.

3) Auto-inclusion will be activated, i.e. Plug automatically starts looking for Z-Wave network controller. Auto-inclusion activation is signaled by a single, RGB LED indicator blink fast in blue.

4) Smart Plug should be recognized and automatically included into the Z-Wave network.

Manual Z-Wave network inclusion:

1) Connect the power supply.

2) Set the Z-Wave network main controller into inclusion mode.

3) Triple click the Z-button, RGB LED indicator should blink fast in blue.

4) Smart Plug should be recognized and included into the Z-Wave network.

Included as a secure device:

1) Connect the power supply.

2) Set the Z-Wave network main controller into secure inclusion mode.

3) Press and hold the Z-button for more than 3 seconds, RGB LED indicator should blink fast in green.

4) Smart Plug should be recognized and included into the Z-Wave security network.

Exclusion Information

To remove Smart Plug from the Z-Wave network:

1) Insert the plug into a socket.

2) Set the Z-Wave network main controller into exclusion mode.

3) Triple click the Z-button.

4) RGB LED indicator will blink orange till the removing process is completed, then the indicator will keep orange for 3 seconds.

Channels

The following table summarises the channels available for the HKZW-SO05 Smart Plug.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number   Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the HKZW-SO05 Smart Plug. Detailed information on each parameter can be found below.

Parameter Description
21: Device Status After Power Failure. Define how the Plug reacts after the power supply is back on.
24: Load Status Change Notification Send notification to associated devices when load is changed.
27: Indicator Modes The RGB LED indicator will indicate the load.
151: Power Report Threshold Power threashold for when to send reports to associated devices
152: Power Report Percentage Threshold Percentage threshold for when to send report to associated devices
171: Power Report Frequence The interval of sending power report to association device.
172: Energy Report Frequence The interval of sending energy report to association device.
173: Voltage Report Frequency The interval of sending voltage report to association device.
174: Electricity Report Frequency The interval of sending electricity report to association device.
20: Overload Protection Turn off if the load power exceeds 0.5A for more than 5s.
1: Lifeline Meter, Basic etc.

21: Device Status After Power Failure.

Define how the Plug reacts after the power supply is back on.

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 0
Options Memorizes its state after a power failure (0)      
  Always on after power failure. (1)      
  Always off after power failure. (2)      

24: Load Status Change Notification

Send notification to associated devices when load is changed.

Property Value      
Configuration ID config_24_1      
Data Type INTEGER   Default Value 1
Options Function is disabled (0)      
  Send Basic Report (1)      
  Only when load condition is not changed by command. (2)      

27: Indicator Modes

The RGB LED indicator will indicate the load.

Property Value      
Configuration ID config_27_1      
Data Type INTEGER   Default Value 0
Options Will work in indicator mode. (0)      
  Indicate load for 5 seconds after load has changed. (1)      

151: Power Report Threshold

Power threashold for when to send reports to associated devices

Overview

When the change value of the load power exceeds the threshold, the meter report is send to associated devices.  0 – The function is disabled.

Property Value
Configuration ID config_151_2
Data Type INTEGER
Range 0 to 65535
Default Value 50

152: Power Report Percentage Threshold

Percentage threshold for when to send report to associated devices

Overview

When the change value of the load power exceeds the threshold, the meter report is send to associated devices.

0 – The function is disabled.

Property Value
Configuration ID config_152_1
Data Type INTEGER
Range 0 to 255
Default Value 10

171: Power Report Frequence

The interval of sending power report to association device.

Overview

The interval of sending power report to association device.

0 = The function is disabled.

Property Value
Configuration ID config_171_4
Data Type INTEGER
Range 5 to 2678400
Default Value 30

172: Energy Report Frequence

The interval of sending energy report to association device.

Overview

The interval of sending energy report to association device.

0 = The function is disabled.

Property Value
Configuration ID config_172_4
Data Type INTEGER
Range 5 to 2678400
Default Value 300

173: Voltage Report Frequency

The interval of sending voltage report to association device.

Overview

The interval of sending voltage report to association device.

0 = The function is disabled.

Property Value
Configuration ID config_173_4
Data Type INTEGER
Range 0 to 2678400
Default Value 0

174: Electricity Report Frequency

The interval of sending electricity report to association device.

Overview

The interval of sending electricity report to association device.

0 = The function is disabled.

Property Value
Configuration ID config_174_4
Data Type INTEGER
Range 0 to 2678400
Default Value 0

20: Overload Protection

Turn off if the load power exceeds 0.5A for more than 5s.

Property Value      
Configuration ID config_20_1_wo      
Data Type INTEGER   Default Value 1
Options Function Disabled (0)      
  Function enabled (1)      

1: Lifeline

Meter, Basic etc.

Property Value
Configuration ID group_1
Data Type TEXT
Range to