HS1HT-Z Temperature/Humidity Sensor

This describes the Z-Wave device HS1HT-Z *, manufactured by *Heiman Technology Co. Ltd with the thing type UID of heiman_hs1htz_00_000.

The device is in the category of Sensor, defining Device used to measure something.

HS1HT-Z  product image

The HS1HT-Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The HS1HT-Z does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Overview

Smart Temperature and Humidity Sensor is designed to detect the temperature and humidity in house, and reports the abnormal conditions to users’ mobile phone, Users could also check the real-time temperature and humidity via mobile phone, The sensor adopts Z-Wave wireless communication protocol with high sensitivity.

See:
https://products.z-wavealliance.org/products/2321
and
http://www.heimantech.com/product/80.html

Inclusion Information

Click [Add] icon in Z-Wave Controller.
- Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.
- If Inclusion Process is successful, Green LED will turn off.

Exclusion Information

Click [Remove] icon in Z-Wave Controller.
- Press the Net_Button 3 times within 1.5s
- If Exclusion Process is successful, Green LED is Blinking 6 times, then turn off

Channels

The following table summarises the channels available for the HS1HT-Z -:

Channel Channel Id Category Item Type
Sensor (temperature) sensor_temperature Temperature Number
Sensor (relative humidity) sensor_relhumidity Humidity Number
Battery Level battery-level Battery Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The device has no configuration parameters configured.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The HS1HT-Z supports 3 association groups.

Group 1: Lifeline

Association group 1: Lifeline association group Maximum supported node is 1. Include command classes: Battery report, multilevel sensor report, and Device Reset Locally. This group supports 1 nodes.

Group 2: Multilevel sensor temperature

Association group 2: Root Device group(multilevel sensor temperature) Maximum supported nodes are 5. 1- multilevel Sensor reports status of the temperature via Lifeline. 2-When the sensor detects status of the temperature, the device will be triggered. This group supports 5 nodes.

Group 3: Multilevel sensor humidity

Association group 3: Root Device group(multilevel sensor humidity) Maximum supported nodes are 5. 1-multilevel Sensor reports status of the humidity via Lifeline. 2-When the sensor detects status of the humidity , the device will be triggered. This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SENSOR_MULTILEVEL_V10 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V2  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_WAKE_UP_V2  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.