The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

HS2WD-Z Smart Siren

This describes the Z-Wave device HS2WD-Z, manufactured by Heiman Technology Co. Ltd with the thing type UID of heiman_hs2wdz_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

HS2WD-Z product image

The HS2WD-Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

Product support sound and light alarm.

Inclusion Information

  • Press the pin-hole 3 times within 1.5s, Green LED is Blinking 3 times within 1.5 second.
  • If add Process is successful, Green LED will turn off.

Exclusion Information

  • Press the pin-hole 3 times within 1.5 second.
  • If remove Process is successful, Green LED is Blinking 6 times, then turn off.

Channels

The following table summarises the channels available for the HS2WD-Z -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Battery Level battery-level Battery Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The device has no configuration parameters configured.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The HS2WD-Z supports 1 association group.

Group 1: Lifeline

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.