The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

HS-WD100+ Scene Capable Wall Dimmer Switch

This describes the Z-Wave device HS-WD100+, manufactured by HomeSeer Technologies with the thing type UID of homeseer_hswd100_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

HS-WD100+ product image

The HS-WD100+ supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the HS-WD100+ -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number   Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the HS-WD100+. Detailed information on each parameter can be found in the sections below.

Param Name Description
4 Orientation Controls the on/off orientation of the rocker switch
7 Remote Dimming Level Increment Number of levels (1-99) to change dimming each step when controlled remotely
8 Remote Dimming Step Duration Time interval (in tens of ms) of brightness change when controlled remotely
9 Local Dimming Level Increment Number of levels (1-99) to change dimming each step when controlled locally
10 Local Dimming Step Duration Time interval (in tens of ms) of brightness change when controlled locally
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 4: Orientation

Controls the on/off orientation of the rocker switch

The following option values may be configured -:

Value Description
0 Normal
1 Inverted

The manufacturer defined default value is 0 (Normal).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 7: Remote Dimming Level Increment

Number of levels (1-99) to change dimming each step when controlled remotely This is the step value that the dimmer level is incremented or decremented for each step duration when controlled remotely.

(This parameter was added in firmware version 5.14) Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Remote Dimming Step Duration

Time interval (in tens of ms) of brightness change when controlled remotely Select time interval to move to the next brightness level. The larger the number, the slower the adjustment to dim levels.

(This parameter was added in firmware version 5.14) Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Local Dimming Level Increment

Number of levels (1-99) to change dimming each step when controlled locally This is the step value that the dimmer level is incremented or decremented for each step duration when controlled locally. Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Local Dimming Step Duration

Time interval (in tens of ms) of brightness change when controlled locally Select time interval to move to the next brightness level. The larger the number, the slower the adjustment to dim levels. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The HS-WD100+ supports 1 association group.

Group 1: Lifeline

Lifeline association only supports the “manual reset” event. This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_SCENE_ACTIVATION_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_CENTRAL_SCENE_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.