HS-WS200+ Scene Capable Wall Switch

This describes the Z-Wave device HS-WS200+, manufactured by HomeSeer Technologies with the thing type UID of homeseer_hsws200_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

HS-WS200+ product image

The HS-WS200+ supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

HS-WS200+ is a Z-Wave Plus relay (on-off) wall switch for use with most lighting and appliance loads. The switch includes an RBG LED indicator which may be controlled wirelessly to suit color preferences or to reflect the changing status of other devices in your home. HS-WS200+ is also designed to trigger automation events with a multi-tap operation (up to 5 taps).

Inclusion Information

Tap the paddle of your HomeSeer switch to begin the inclusion process. This will take a few moments to complete.

Exclusion Information

Put your Z-Wave controller into exclusion mode. Tap the paddle of your HomeSeer switch.

Channels

The following table summarises the channels available for the HS-WS200+ -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Scene Number scene_number   Number
Mode of Operation config_decimal   Decimal
Status LED Color config_decimal   Decimal

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Mode of Operation

Sets dimmer mode of operation.

0=Normal mode (load status) 1=Status mode (custom status)

Generic class for configuration parameter.

The config_decimal channel supports the Decimal item.

Status LED Color

Possible values: 0-7

0=Off, 1=Red, 2=Green, 3=Blue, 4=Magenta, 5=Yellow, 6=Cyan, 7=White

Generic class for configuration parameter.

The config_decimal channel supports the Decimal item.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the HS-WS200+. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Bottom LED Operation Sets LED operation (in normal mode)
4 Orientation Sets paddle’s load orientation
13 Status Mode Sets switch mode of operation
14 Load Status LED Color Sets the Normal mode LED color
21 Status LED Color Sets the Status mode LED color
31 Blink Frequency Sets the switch LED Blink frequency
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Bottom LED Operation

Sets LED operation (in normal mode)

The following option values may be configured -:

Value Description
0 LED ON if load is OFF
1 LED OFF if load is OFF

The manufacturer defined default value is 0 (LED ON if load is OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Orientation

Sets paddle’s load orientation

The following option values may be configured -:

Value Description
0 Top of Paddle turns load ON
1 Bottom of Paddle turns load ON

The manufacturer defined default value is 0 (Top of Paddle turns load ON).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 13: Status Mode

Sets switch mode of operation

The following option values may be configured -:

Value Description
0 Normal mode (load status)
1 Status mode (custom status)

The manufacturer defined default value is 0 (Normal mode (load status)).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Load Status LED Color

Sets the Normal mode LED color

The following option values may be configured -:

Value Description
0 White
1 Red
2 Green
3 Blue
4 Magenta
5 Yellow
6 Cyan

The manufacturer defined default value is 0 (White).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 21: Status LED Color

Sets the Status mode LED color

The following option values may be configured -:

Value Description
0 Off
1 Red
2 Green
3 Blue
4 Magenta
5 Yellow
6 Cyan
7 White

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Sets the switch LED Blink frequency

The following option values may be configured -:

Value Description
0 No blink
1 100ms ON then 100ms OFF

The manufacturer defined default value is 0 (No blink).

This parameter has the configuration ID config_31_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The HS-WS200+ supports 1 association group.

Group 1: Lifeline

Lifeline association only supports the “manual reset” event. This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_SCENE_ACTIVATION_V1  
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_CENTRAL_SCENE_V3  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  