EZMultiPli Multi Sensor

This describes the Z-Wave device EZMultiPli, manufactured by Express Controls with the thing type UID of homeseer_ezmultipli_00_000.

Multi Sensor

Channels

The following table summarises the channels available for the EZMultiPli Multi Sensor.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Color color_color color_color   Color
Alarm alarm_general alarm_general Door Switch

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the EZMultiPli Multi Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: OnTime OnTime sets the number of minutes that the lights stay on when motion has not been detecte…
2: OnLevel OnLevel is the value sent by the Z-Wave BASIC_SET command to all Association Group 2 node…
3: LiteMin A Luminance report is sent to the system controller every LiteMin minutes.
4: TempMin A Temperature report is sent to the controller every TempMin minutes.
5: TempAdj TempAdj is a twos-complement number that is used to adjust the temperature reading to make…
1: LIFELINE This group is normally automatically assigned to the Z-Wave system controller when EZMulti…
2: BASIC This group is used to directly turn lights on or off when motion is detected.

1: OnTime

OnTime sets the number of minutes that the lights stay on when motion has not been detected.

Overview

OnTime sets the number of minutes that the lights stay on when motion has not been detected.

A value of 0 is a special mode where the lights are constantly sent a command to turn them on whenever motion is detected. EZMultiPli will NOT turn the lights off in this mode.

Recommended values:

  • 5 min for hallways
  • 20 min for an office environment
  • 60 min for a library, office or other room where someone may be sitting still for a long time
Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 127
Default Value 10

2: OnLevel

OnLevel is the value sent by the Z-Wave BASIC_SET command to all Association Group 2 nodes when motion is detected.

Overview

OnLevel is the value sent by the Z-Wave BASIC_SET command to all Association Group 2 nodes when motion is detected.

A value of 0 will turn the lights off (not recommended). A value between 1 and 99 will set the dim level to between 1% and 99% (99% is full on).

A value of -1 will turn the light “on” which depends on the device but most will set the dim level to the last dim setting.

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range -1 to 99
Default Value -1

3: LiteMin

A Luminance report is sent to the system controller every LiteMin minutes.

Overview

A Luminance report is sent to the system controller every LiteMin minutes.

A value of zero turns this mode off. Luminance values can still be obtained at any time by the home control application in this mode

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 127
Default Value 60

4: TempMin

A Temperature report is sent to the controller every TempMin minutes.

Overview

A Temperature report is sent to the controller every TempMin minutes.

A value of zero turns this mode off. Temperature values can still be obtained at any time by polling the status of the temperature sensor.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 127
Default Value 60

5: TempAdj

TempAdj is a twos-complement number that is used to adjust the temperature reading to make it more accurate.

Overview

TempAdj is a twos-complement number that is used to adjust the temperature reading to make it more accurate. The value is in tenths of degree Fahrenheit. The temperature reading can be adjusted by +12.7F to -12.8F. A value of 1 will adjust the temperature reading by +0.1F. A value of -1 will adjust the temperature by -0.1F. A value of 123 will adjust the temperature by +12.3F. 

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range -127 to 128
Default Value 0

1: LIFELINE

This group is normally automatically assigned to the Z-Wave system controller when EZMultiPli is added to the ZWave network.

Overview

This group is normally automatically assigned to the Z-Wave system controller when EZMultiPli is added to the ZWave network. All Notification command class reports (motion detection) are sent to the node assigned to this group. Advanced lighting control should be handled by a home control application based on these reports.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: BASIC

This group is used to directly turn lights on or off when motion is detected.

Overview

This group is used to directly turn lights on or off when motion is detected. Up to four (4) Z-Wave devices can be associated in this group. EZMultiPli will send a BASIC ON command to all devices that are associated in this group. Note that the Z-Wave devices in this group must be within direct range (about 30’) of EZMultiPli. Control of nodes that are further away or blocked by metal or concrete walls should rely on the Z-Wave system controller and the home-control application for reliable operation. Note that including the NodeID of EZMultiPli in this group will control the LED which will come on when motion is detected and goes off when no motion has been detected for OnTime minutes.

Property Value
Configuration ID group_2
Data Type TEXT
Range to