SIR-321 RF Countdown Timer

This describes the Z-Wave device SIR-321, manufactured by Horstmann Controls Limited with the thing type UID of horstmann_sir321_00_000.

SIR-321 product image

The SIR-321 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

Wirelessly controllable 3 KW wall switch timer function

Channels

The following table summarises the channels available for the SIR-321 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Temperature sensor_temperature Temperature Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Temperature

This is what is generated in the zwave node file: SENSOR\_MULTILEVEL 1 1 1 TEMPERATURE TEMPERATURE true true

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the SIR-321. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Fail Save timer Enable/Disable the Fail save timer
2 Temperature Scale Set the Temperatur scale to Celsius
3 Temperature reporting intervals Define the time interval for the temperature report that is sent.
4 Delta configuration temperature reporting Set the delta-configuration of the temperature report in Celsius or Fahrenheit
5 Temperature Cutoff Set the Cutoff in Celsius

Parameter 1: Fail Save timer

Enable/Disable the Fail save timer

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Temperature Scale

Set the Temperatur scale to Celsius

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Temperature reporting intervals

Define the time interval for the temperature report that is sent.

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Delta configuration temperature reporting

Set the delta-configuration of the temperature report in Celsius or Fahrenheit

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Temperature Cutoff

Set the Cutoff in Celsius

Values in the range 0 to 1000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The SIR-321 supports 2 association groups.

Group 1: Group 1

Group 1 This group supports 4 nodes.

Group 2: Group 2

Group 2 This group supports 4 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_MULTILEVEL_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.