SSR-302 Two Channel Boiler Actuator

This describes the Z-Wave device SSR-302, manufactured by Horstmann Controls Limited with the thing type UID of horstmann_ssr302_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

The SSR-302 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The SSR-302 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the SSR-302 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Thermostat mode thermostat_mode Temperature Number
Switch 1 switch_binary1 Switch Switch
Thermostat mode 1 thermostat_mode1 Temperature Number
Switch 2 switch_binary2 Switch Switch
Thermostat mode 2 thermostat_mode2 Temperature Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away
15 Full Power
31 Manufacturer Specific

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Thermostat mode 1

Sets the thermostat.

The thermostat_mode1 channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away
15 Full Power
31 Manufacturer Specific

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Thermostat mode 2

Sets the thermostat.

The thermostat_mode2 channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away
15 Full Power
31 Manufacturer Specific

Device Configuration

The device has no configuration parameters configured.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_THERMOSTAT_MODE_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_VERSION_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_THERMOSTAT_MODE_V1| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V1  
COMMAND_CLASS_THERMOSTAT_MODE_V1  