SIR-321 RF Countdown Timer

This describes the Z-Wave device SIR-321, manufactured by Horstmann Controls Limited with the thing type UID of horstmann_sir321_00_000.

RF Countdown Timer

Overview

Wirelessly controllable 3 KW wall switch timer function

Channels

The following table summarises the channels available for the SIR-321 RF Countdown Timer.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Temperature sensor_temperature sensor_temperature Temperature Number

Temperature

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the SIR-321 RF Countdown Timer. Detailed information on each parameter can be found below.

Parameter Description
1: Fail Save timer Enable/Disable the Fail save timer
2: Temperature Scale Set the Temperatur scale to Celsius
3: Temperature reporting intervals Define the time interval for the temperature report that is sent.
4: Delta configuration temperature reporting Set the delta-configuration of the temperature report in Celsius or Fahrenheit
5: Temperature Cutoff Set the Cutoff in Celsius
1: Group 1 Group 1
2: Group 2 Group 2

1: Fail Save timer

Enable/Disable the Fail save timer

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 0

2: Temperature Scale

Set the Temperatur scale to Celsius

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 127
Default Value 0

3: Temperature reporting intervals

Define the time interval for the temperature report that is sent.

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 32767
Default Value 0

4: Delta configuration temperature reporting

Set the delta-configuration of the temperature report in Celsius or Fahrenheit

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 100
Default Value 0

5: Temperature Cutoff

Set the Cutoff in Celsius

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 1000
Default Value 0

1: Group 1

Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.