SWM301 Z-Wave Module for Water Meter

This describes the Z-Wave device SWM301, manufactured by Horstmann Controls Limited with the thing type UID of horstmann_swm301_00_000.

Z-Wave Module for Water Meter

Overview

SWM 301 is a battery-powered RF module using Z-Wave® technology for reporting secondary water metering readings in domestic dwellings.

The RF module records the meter reading by backlash-free pick-up on the litre wheel of the meter register and transmits the data over the Zwave network either on a time or delta change.

Inclusion Information

  1. Put network controller in Inclusion / Exclusion mode.
  2. Hold a small magnet near to reed switch until the LED is turned on. Remove magnet right away when LED turned on. LED will remain on for next 4 seconds and then it will flash once to indicate NIF is sent.
  3. Repeat the step 2 if LED is not flashed once.
  4. The controller will indicate the successful inclusion/ exclusion operation.

Wakeup Information

Hold a small magnet near to reed switch until the LED is turned on. Remove magnet right away when LED turned on. LED will remain on for next 4 seconds and then it will flash once to indicate NIF is sent.

SWM301 will wake up for 10 seconds after sending NIF

Channels

The following table summarises the channels available for the SWM301 Z-Wave Module for Water Meter.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Water meter (amps) meter_water_cubic_meters meter_water_cubic_meters Energy Number
  battery-level system.battery-level    
Alarm (heat) alarm_heat alarm_heat   Switch

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the SWM301 Z-Wave Module for Water Meter. Detailed information on each parameter can be found below.

Parameter Description
1: Meter register offset current meter reading
2: Meter reading reporting intervals how often meter reading is sent
3: Delta config for meter reading min. delta for automatic report
4: Mechanical meter serial number  
5: Temperature monitor on / off enable temperature monitor
6: Temperature delta change in temperature for report
7: Temperature Alarm Threshold temperature triggering alarm
1: Meter reading Group receiving meter readings
2: low battery Group receiving battery warnings
3: Temperature and low temp alarm Group receiving temperature

1: Meter register offset

current meter reading

Overview

Offset to adjust the reported to the actual meter reading.

Property Value
Configuration ID config_1_4
Data Type INTEGER
Range 0 to 99999999
Default Value 0

2: Meter reading reporting intervals

how often meter reading is sent

Overview

Defines how often the meter reading is sent.

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 10000
Default Value 1440

3: Delta config for meter reading

min. delta for automatic report

Overview

Defines the minimum change of the meter reading that results in an unsolicited meter report.

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 10000
Default Value 0

4: Mechanical meter serial number

Property Value
Configuration ID config_4_4
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

5: Temperature monitor on / off

enable temperature monitor

Overview

Enables or disables the temperature monitor.

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 0 to 1
Default Value 0

6: Temperature delta

change in temperature for report

Overview

Defines how much the temperature has to change for an unsolicited temperature report.

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 0 to 30
Default Value 0

7: Temperature Alarm Threshold

temperature triggering alarm

Overview

Defines below what temperature a low temperature alarm is reported.

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 0 to 40
Default Value 0

1: Meter reading

Group receiving meter readings

Overview

Group 1 - Nodes to receive unsolicited water meter reading.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: low battery

Group receiving battery warnings

Overview

Group 2 - Nodes to receive unsolicited low battery warnings report.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Temperature and low temp alarm

Group receiving temperature

Overview

Group 3 - Nodes to receive unsolicited temperature report and low temperature alarm.

Property Value
Configuration ID group_3
Data Type TEXT
Range to