SmartDimmer RAone SmartDimmer

This describes the Z-Wave device SmartDimmer, manufactured by INNOVUS with the thing type UID of innovus_00110001_01_000.

RAone SmartDimmer

Channels

The following table summarises the channels available for the SmartDimmer RAone SmartDimmer.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Sensor (Power in watts) sensor_power sensor_power Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the SmartDimmer RAone SmartDimmer. Detailed information on each parameter can be found below.

Parameter Description
0: Maximum dim level Maximum dim level
1: Report node Report Node, reports changes in level to this node id. Disabled if 0.
2: B&O IR support B&O IR support is disabled if 0 otherwise enabled.
3: Dimming type Dimming Type, trailing edge enabled if 0 otherwise leading edge enabled.
4: Dimming level duration Dimming level duration
5: Set level duration Default Set Level Duration, how long time it takes to set one level in 0.01s.
6: Long dim duration Long dim duration
7: Touch press time Touch press time
8: Touch Multiple Press Time No specific usage in this product
9: Touch Hold Time Touch Hold Time
10: Network Update Interval Network Update Interval
11: Rediscover Interval Rediscover Interval, time between rediscoveries in 256 seconds. Disabled if 0.
1: Dimmer  

0: Maximum dim level

Maximum dim level

Overview

Maximum Level, a limit on the maximum level the dimmer can reach. Levels larger than 99 will simply be interpreted as 99 ie. no limit.

Property Value
Configuration ID config_0_1
Data Type INTEGER
Range 0 to 99
Default Value 99

1: Report node

Report Node, reports changes in level to this node id. Disabled if 0.

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 0

2: B&O IR support

B&O IR support is disabled if 0 otherwise enabled.

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options disabled (0)      
  enabled (1)      

3: Dimming type

Dimming Type, trailing edge enabled if 0 otherwise leading edge enabled.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options Trailing edge (0)      
  Leading edge (1)      

4: Dimming level duration

Dimming level duration

Overview

Default Dimming Level Duration, how long time it takes to dim one level in 0.01s.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 255
Default Value 8

5: Set level duration

Default Set Level Duration, how long time it takes to set one level in 0.01s.

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 1 to 255
Default Value 1

6: Long dim duration

Long dim duration

Overview

Long Dim Duration, time to use dimming to level 0 when double clicking. Format is the same as multilevel switch duration.

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 0 to 255
Default Value 158

7: Touch press time

Touch press time

Overview

Touch Press Time, time for presses to register as separate and not part of a sequence, measured in 0.01s. 0 is interpreted as a 1.

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 255
Default Value 50

8: Touch Multiple Press Time

No specific usage in this product

Overview

Touch Multiple Press Time, has no specific usage is this product, shouldn’t be changed.

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range 0 to 255
Default Value 100

9: Touch Hold Time

Touch Hold Time

Overview

Touch Hold Time, time for presses to register as being held down in 0.01s. 0 is interpreted as a 1.

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 255
Default Value 40

10: Network Update Interval

Network Update Interval

Overview

Network Update Interval, time between network updates in 256 seconds. Disabled if 0.

Property Value
Configuration ID config_10_2
Data Type INTEGER
Range 0 to 65535
Default Value 168

11: Rediscover Interval

Rediscover Interval, time between rediscoveries in 256 seconds. Disabled if 0.

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 65535
Default Value 2362

1: Dimmer

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.