TP-802ZD Door/Window Sensor

This describes the Z-Wave device TP-802ZD, manufactured by Kaipule Technology Co., Ltd. with the thing type UID of kaipule_doorwindowsensor_00_000.

Door/Window Sensor

Overview

The sensor must be added to the Zwave network prior to use.

- This sensor can not work alone, need connect to Z-wave gateway - First time connect, the distance between sensor and gateway better less than 1.0 meter, after connected, then install the sensor where you need - When connect to gateway, choose add device in your gateway software, then quickly click the sensor’s z-wave trigger 3 times to send signal to gateway, delet device similar operation - When install, the door sensor main part and magnetic stripe gap must less than 5mm - The work distance to gateway is 10 to 20 meters indoor, more wall or barrier will influence the distance

Factory Setting
Press the tamper switch 6 times in 2s, it will recover to factory setting after a period of time
(Please use the reset procedure only when the primary controller is missing or inoperable)

Inclusion Information

To include the sensor in a networks start by placing the controller in inclusion mode. Then activate the inclusion mode at the sensor by pressing the tamper switch 3 times within 1.5s.

Exclusion Information

To exclude the sensor in a networks start by placing the controller in exclusion mode. Then activate the exclusion mode at the sensor by pressing the tamper switch 3 times within 1.5s.

Wakeup Information

a) Manual Wake-up
Quickly press tamper switch once, the door sensor will automatically send wake-up
information, and there will be 10s after wake-up to receive gateway setting information.
b) Automatic Wake-up
Default time of automatic wake-up is 24 hours, and there will be 10s after wake-up to receive
gateway setting information, the max automatic report time = 24 hours, minimum=30min

Channels

The following table summarises the channels available for the TP-802ZD Door/Window Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (access) alarm_access alarm_access Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the TP-802ZD Door/Window Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Set Level Basic Set Command will be sent when the door/window is opened or closed
2: Turn Off Light Time Configuration Turn Off Light Time
3: Door Sensor Status Report Auto report Door/Window status time
1: Group 1 Is assigned to the device status - OPEN/CLOSED.
2: Group 2 Sending control commands to associated devices

1: Basic Set Level

Basic Set Command will be sent when the door/window is opened or closed

Overview

If there is any device under Association Group2, the door sensor will send “Basic Set = value”
command to control that device when the door sensor is opened.

“Value” configuration rule is as below:

Available settings:

1 to 100 Dimmer Level

255 (Default) For ON/OFF Light Only

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 1 to 100
Default Value 255

2: Turn Off Light Time Configuration

Turn Off Light Time

Overview

If there is any device under Association Group2, the door sensor will send “Basic Set = value”
command to Group2, and send “Basic Set = 0x00” command to turn-off light after “t” seconds,
Set value = “t”, means to send Basic Set command after “t” seconds.

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 1 to 120
Default Value 20

3: Door Sensor Status Report

Auto report Door/Window status time

Overview

Under normal working status (without trigger), the door sensor will automatically send report
to the Gateway about its current tamper & open/close status. Set value = t, means “t” hours,
(“t”=0, means no status report)

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 24
Default Value 12

1: Group 1

Is assigned to the device status - OPEN/CLOSED.

Overview

1.It will send “NOTIFICATION_REPORT”to the device in Group 1 when the door sensor is opened / closed, tamper switch is triggered / recovered.

2.When in low battery status, door sensor will send “BATTERY_REPORT” to Group 1 device periodically.

3.The door sensor will send “DEVICE_RESET_LOCALLY_NOTIFICATION” to Group1 device when the device recovers to factory settings.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Sending control commands to associated devices

Overview

When the door sensor is opened, it will send “BASIC SET” command to control these devices in Group2.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.