ES-61 Smoke Sensor

This describes the Z-Wave device ES-61, manufactured by Kaipule Technology Co., Ltd. with the thing type UID of kaipule_es61_01_036.

Smoke Sensor

Channels

The following table summarises the channels available for the ES-61 Smoke Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (smoke) alarm_smoke alarm_smoke Door Switch
Alarm (tamper) alarm_tamper alarm_tamper   Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the ES-61 Smoke Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Set If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value c…
2: Turn Off Light Time Configuration If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value c…
3: PIR Sensor Alarm Elemination Time Configuration Min time is 5s. Eg If the config is 1, this means it will eliminate alarm after 1 * 5s = …
1: Lifeline Send “notification_Report” to the device in Life line group
2: Basic Set Command  

1: Basic Set

If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to control that deivce when the PIR is triggered.

Overview

If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to control that deivce when the PIR is triggered.

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 1 to 100
Default Value 255

2: Turn Off Light Time Configuration

If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to Group 2 and send Basic Set = 0x00 to turn of light after 5 x t seconds- Set value t means to send the BAsic Set command after t seconds.

Overview

If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to Group 2 and send Basic Set = 0x00 to turn of light after 5 x t seconds- Set value t means to send the BAsic Set command after t seconds.

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 1 to 120
Default Value 20

3: PIR Sensor Alarm Elemination Time Configuration

Min time is 5s. Eg If the config is 1, this means it will eliminate alarm after 1 * 5s = 5 seconds

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 120
Default Value 20

1: Lifeline

Send “notification_Report” to the device in Life line group

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic Set Command

Overview

When sensor is triggered:

[Command Class BAsic, Basic Set, Value = 0xFF(default 0xFF, configurable, see Config Parameters)

When light up timeout:

[Command Class BAsic, BAsic Set, Value =0x00]

Property Value
Configuration ID group_2
Data Type TEXT
Range to