IM-20 Door Sensor

This describes the Z-Wave device IM-20, manufactured by Kaipule Technology Co., Ltd. with the thing type UID of kaipule_im20_00_000.

Door Sensor

Overview

Factory Setting
Press the tamper switch 6 times in 2s, it will recover to factory setting after a period of time
(Please use the reset procedure only when the primary controller is missing or inoperable)

Inclusion Information

Enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s,
then the door sensor will stay in enrollment state until successfully enrolled into network or
enrollment time out after 30s.

Exclusion Information

Enter the Exclusion Mode of gateway, and press the tamper switch 3 times within
1.5s, then the door sensor will be removed after a period of time.

Wakeup Information

a) Manual Wake-up
Quickly press tamper switch once, the door sensor will automatically send wake-up
information, and there will be 10s after wake-up to receive gateway setting information.
b) Automatic Wake-up
Default time of automatic wake-up is 24 hours, and there will be 10s after wake-up to receive
gateway setting information, the max automatic report time = 24 hours, minimum=30min

Channels

The following table summarises the channels available for the IM-20 Door Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (access) alarm_access alarm_access Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the IM-20 Door Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Group 1  

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to