DP-32 / IX-30 / IX-32 PIR Sensor

This describes the Z-Wave device DP-32 / IX-30 / IX-32, manufactured by Kaipule Technology Co., Ltd. with the thing type UID of kaipule_ix32_06_000.

PIR Sensor

Overview

The hardware board for the IX30 (wall) and IX32 (ceiling) is the same thing and reports the same Type and ID.

Channels

The following table summarises the channels available for the DP-32 / IX-30 / IX-32 PIR Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Motion Alarm alarm_motion alarm_motion Door Switch
Tamper Alarm alarm_tamper alarm_tamper   Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the DP-32 / IX-30 / IX-32 PIR Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Set If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value c…
2: Turn Off Light Time Configuration If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value c…
3: PIR Sensor Alarm Elemination Time Configuration Min time is 5s. Eg If the config is 1, this means it will eliminate alarm after 1 * 5s = …
1: Lifeline Send “notification_Report” to the device in Life line group
2: Basic Set Command  

1: Basic Set

If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to control that deivce when the PIR is triggered.

Overview

If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to control that deivce when the PIR is triggered.

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 1 to 100
Default Value 255

2: Turn Off Light Time Configuration

If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to Group 2 and send Basic Set = 0x00 to turn of light after 5 x t seconds- Set value t means to send the BAsic Set command after t seconds.

Overview

If there is any device in Association Group 2 the PIR Sensor will send BASIC Set = Value command to Group 2 and send Basic Set = 0x00 to turn of light after 5 x t seconds- Set value t means to send the BAsic Set command after t seconds.

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 1 to 120
Default Value 20

3: PIR Sensor Alarm Elemination Time Configuration

Min time is 5s. Eg If the config is 1, this means it will eliminate alarm after 1 * 5s = 5 seconds

Overview

The selected value is multiplied with 5. After this time the sensor will report PIR OFF.

E.g. If you select value –> 3 * 5s = 15 seconds.

The Sensor will report PIR Off after 15 seconds.

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 120
Default Value 20

1: Lifeline

Send “notification_Report” to the device in Life line group

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Basic Set Command

Overview

When sensor is triggered:

[Command Class BAsic, Basic Set, Value = 0xFF(default 0xFF, configurable, see Config Parameters)

When light up timeout:

[Command Class BAsic, BAsic Set, Value =0x00]

Property Value
Configuration ID group_2
Data Type TEXT
Range to