15DC200 200W Design Pro LED Controller

This describes the Z-Wave device 15DC200, manufactured by Kichler with the thing type UID of kichler_15dc200_00_000.

The 15DC200 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the 15DC200 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Clock Time Offset time_offset Temperature Number
Switch 1 switch_binary1 Switch Switch
Switch 2 switch_binary2 Switch Switch
Switch 3 switch_binary3 Switch Switch
Switch 4 switch_binary4 Switch Switch
Switch 5 switch_binary5 Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel supports the Number item and is in the Temperature category.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Switch 3

Switch the power on and off.

The switch_binary3 channel supports the Switch item and is in the Switch category.

Switch 4

Switch the power on and off.

The switch_binary4 channel supports the Switch item and is in the Switch category.

Switch 5

Switch the power on and off.

The switch_binary5 channel supports the Switch item and is in the Switch category.

Device Configuration

The device has no configuration parameters configured.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_TIME_V1| | | COMMAND_CLASS_TIME_PARAMETERS_V1| | | COMMAND_CLASS_GEOGRAPHIC_LOCATION_V0| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC|

Endpoint 2

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC|

Endpoint 3

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC|

Endpoint 4

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC|

Endpoint 5

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.