914TRL Touchpad Electronic Deadbolt

This describes the Z-Wave device 914TRL, manufactured by Black & Decker with the thing type UID of kwikset_914trl_00_000.

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

914TRL product image

The 914TRL supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

The following table provides a reference of the Alarm_Number related messages.

Alarm Type Alarm Level Notification Event

021 001 Lock Secured using Keyed cylinder or inside thumb-turn

022 001 Lock Un-Secured using Keyed cylinder or inside thumb-turn

026 001 Lock Auto Secured – Bolt Jammed (Not fully extended)

027 001 Lock Auto Secured – Successful (Fully extended)

017 001 Lock Secured at Keypad – Bolt Jammed (Not fully extended)

018 000 or User-ID#* Lock Secured at Keypad – Successful (Fully extended)

019 User-ID#* Lock Un-Secured by User (User-ID) at Keypad

023 001 Lock Secured by Controller – Bolt Jammed (Not fully extended)

024 001 Lock Secured by Controller – Successful (Fully extended)

025 001 Lock Un-Secured by Controller – Successful (Fully retracted)

112 User-ID#* New User Code (User-ID#) added to the lock

032 001 All User Codes deleted from lock

161 001 Failed User Code attempt at Keypad

162 User-ID#* Attempted access by user (User-ID#) outside of scheduled

167 001 Low battery level

168 001 Critical battery level

169 001 Battery level too low to operate lock

* User-ID# values: 001 to 030

Inclusion Information

Press button “A” on the lock one time to include it in your system.

Exclusion Information

Press button “A” on the lock one time to exclude it in your system.

Channels

The following table summarises the channels available for the 914TRL -:

Channel Channel Id Category Item Type
Door Lock lock_door Door Switch
Alarm alarm_number    
Alarm Raw alarm_raw   String
Battery Level battery-level Battery Number

Door Lock

Lock and unlock the door.

The lock_door channel supports the Switch item and is in the Door category.

Alarm

Channel type information on this channel is not found.

Alarm Raw

Provides the raw alarm status information including alarm type and level in the following json format:

{“type”:”ACCESS_CONTROL”,”event”:”6”,”status”:”255”}

Provides alarm parameters as json string.

The alarm_raw channel supports the String item. This is a read only channel so will only be updated following state changes from the device.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the 914TRL. Detailed information on each parameter can be found in the sections below.

Param Name Description
31 Auto Buzzer Beeping sound enabled.
31 Auto Lock Automatically re-locks door 30 seconds after unlocking.
31 Lock LED Status Door lock status LED blinks every 6 seconds.
40 Factory Default Reset to factory default settings.
  Lock Timeout Sets the time after which the door will auto lock

Parameter 31: Auto Buzzer

Beeping sound enabled. Beeping sound enabled. When disabled, keypad buttons light red or amber when pressed.

ON position is factory default.

Note: It is recommended that the beeping sound is enabled during programming. The following option values may be configured -:

Value Description
0 OFF
1 ON

The manufacturer defined default value is 1 (ON).

This parameter has the configuration ID config_31_1_00100000 and is of type INTEGER. This is a read only parameter.

Parameter 31: Auto Lock

Automatically re-locks door 30 seconds after unlocking. Lock automatically re-locks door 30 seconds after unlocking. OFF position is factory default. If this switch is turned on, it will be disabled if all codes are deleted from the lock. The following option values may be configured -:

Value Description
0 OFF
1 ON

The manufacturer defined default value is 0 (OFF).

This parameter has the configuration ID config_31_1_01000000 and is of type INTEGER. This is a read only parameter.

Parameter 31: Lock LED Status

Door lock status LED blinks every 6 seconds. Door lock status LED blinks every 6 seconds. ON position is factory default. The following option values may be configured -:

Value Description
0 OFF
1 ON

The manufacturer defined default value is 1 (ON).

This parameter has the configuration ID config_31_1_10000000 and is of type INTEGER. This is a read only parameter.

Parameter 40: Factory Default

Reset to factory default settings. Reset factory default settings, except for the anti-theft setting.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
1 Factory Default

The manufacturer defined default value is 0.

This parameter has the configuration ID config_40_1_wo and is of type INTEGER. This is a write only parameter.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 914TRL supports 1 association group.

Group 1: Group 1

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_DOOR_LOCK_LOGGING_V0  
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V0  
COMMAND_CLASS_DOOR_LOCK_V1  
COMMAND_CLASS_USER_CODE_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_PROTECTION_V1  
COMMAND_CLASS_LOCK_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  
COMMAND_CLASS_TIME_PARAMETERS_V0  
COMMAND_CLASS_SECURITY_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.