WD500Z-1 Wall Dimmer Switch

This describes the Z-Wave device WD500Z-1, manufactured by Linear Corp with the thing type UID of linear_wd500z_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

WD500Z-1 product image

The WD500Z-1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the WD500Z-1 -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the WD500Z-1. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Dim Start Level A dimmer receiving this command will start dimming from that start level if this bit is set to 0. If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level.
3 LED Indication The WD500Z-1 will flicker its LED when it is transmitting to any of its groups.
4 Invert Switch To change the top of the switch to OFF and the bottom to ON change parameter to 1.
14 Enable Shade Control Group 2 The switch can control shade control devices if this parameter is set to 1
15 Enable Shade Control Group 3 The switch can control shade control devices if this parameter is set to 1.
19 LED Transmission Indication The WD500Z-1 will flicker its LED when it is transmitting to any of its groups. Parameter set to 0 = not flicker Parameter set to 1 = flicker the entire time of transmitting Parameter set to 2 = flicker for only 1 second.
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Dim Start Level

A dimmer receiving this command will start dimming from that start level if this bit is set to 0. If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level.

The following option values may be configured -:

Value Description
0 Use Start Level
1 Ignore Start Level

The manufacturer defined default value is 1 (Ignore Start Level).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 3: LED Indication

The WD500Z-1 will flicker its LED when it is transmitting to any of its groups.

The following option values may be configured -:

Value Description
0 0
1 1

The manufacturer defined default value is 0 (0).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

To change the top of the switch to OFF and the bottom to ON change parameter to 1.

The following option values may be configured -:

Value Description
0 Top-ON, Bottom-OFF
1 Bottom-ON, Top-OFF

The manufacturer defined default value is 0 (Top-ON, Bottom-OFF ).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 14: Enable Shade Control Group 2

The switch can control shade control devices if this parameter is set to 1

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Enable Shade Control Group 3

The switch can control shade control devices if this parameter is set to 1.

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 19: LED Transmission Indication

The WD500Z-1 will flicker its LED when it is transmitting to any of its groups. Parameter set to 0 = not flicker Parameter set to 1 = flicker the entire time of transmitting Parameter set to 2 = flicker for only 1 second.

The following option values may be configured -:

Value Description
0 Disable Flicker
1 Flicker while transmitting
2 Flicker for 1 second

The manufacturer defined default value is 2 (Flicker for 1 second).

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The WD500Z-1 supports 3 association groups.

Group 1: UNKNOWN!!!

This group supports 5 nodes.

Group 2: Double Tap

This group supports 5 nodes.

Group 3: Triple Tap

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_SCENE_ACTIVATION_V1  
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V0  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_VERSION_V1  