GoControl GC-TBZ48 Z-Wave Plus Thermostat

This describes the Z-Wave device GoControl GC-TBZ48, manufactured by Linear Corp with the thing type UID of linear_gctbz48_00_000.

Z-Wave Plus Thermostat

Channels

The following table summarises the channels available for the GoControl GC-TBZ48 Z-Wave Plus Thermostat.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Thermostat mode thermostat_mode linear_gctbz48_00_000_thermostat_mode Temperature Number
Thermostat Operating State thermostat_state thermostat_state Temperature Number
Setpoint (cooling) thermostat_setpoint_cooling thermostat_setpoint Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number
Thermostat fan mode thermostat_fanmode linear_gctbz48_00_000_thermostat_fanmode Temperature Number
Thermostat fan state thermostat_fanstate linear_gctbz48_00_000_thermostat_fanstate Temperature Number
  battery-level system.battery-level    
Clock Time Offset time_offset time_offset Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (cooling)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the GoControl GC-TBZ48 Z-Wave Plus Thermostat. Detailed information on each parameter can be found below.

Parameter Description
1: Group 1  
2: Group 2  
3: Group 3  

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.