WA00Z-1 Wall Mounted Switch

This describes the Z-Wave device WA00Z-1, manufactured by Linear Corp with the thing type UID of linear_wa00z1_00_000.

Wall Mounted Switch

Channels

The following table summarises the channels available for the WA00Z-1 Wall Mounted Switch.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the WA00Z-1 Wall Mounted Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Activation of Central Scene Set top and bottom button scene numbers.
2: Control Mode Control other devices or issue various scene activation…
4: Invert Switch Invert top of switch ON/OFF buttons
1: Lifeline  
2: Group 2  
3: Group 3  

1: Activation of Central Scene

Set top and bottom button scene numbers.

Overview

Z-Wave Plus introduces a new process for scene activation – “Central Scene
Control”. Press and release the button, it will send a certain command to the
central controller via the lifeline association group 1. This allows the controller
to react to both a button press and a button release. This mode implements
communication pattern 6, and requires a gateway supporting Z-Wave Plus.

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 99
Default Value 0

2: Control Mode

Control other devices or issue various scene activation…

Overview

…  commands to a central controller.

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 2
Default Value 0

4: Invert Switch

Invert top of switch ON/OFF buttons

Overview

To change the top of the switch to OFF and the bottom of the switch ON, set Parameter 4 to a value of 1.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 1
Default Value 0

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.