LHC5031 DIN Mount Multiple Actuator Controller for Floor Heating

This describes the Z-Wave device LHC5031, manufactured by Logic Home Control with the thing type UID of logic_lhc5031_00_062.

DIN Mount Multiple Actuator Controller for Floor Heating

Overview

LHC 5031 Z-Wave DIN rail module, is a module that clips right onto a DIN rail to add a variety of functions to your wireless Z-Wave network.

LHC5031 is equipped with 10 relay outputs and 4 analogue inputs, and a Z-Wave radio for interfacing to the wireless Z-Wave network. The module can be power supplied from a 230V AC mains connectio, and is able to deliver an output supply of 24V DC.

LHC5031 inputs are able to be freely controlled from the Z-Wave network, and can be used for several purposes, e.g. on/off control of light, control of valve actuators for an underfloor heating system, or control of other home automation systems.

LHC5031 inputs are analogue inputs for interfacing simple temperature sensors; NTC, PT1000, etc.

It is possible to configure the level- and the indication of the status indicator LED in the front of the LHC5031 module.

The device is also known as: Multireg Z-Water from Thermo-Floor.

Inclusion Information

Place your primary controller in Adding mode by following the manufacturers description, then activate the add mode on the deice by clicking the small button through the little hole, marked with the text “INCLUSION”, in front of the LHC5031 module.

Exclusion Information

The device is removed in the same manner that it is included, as long as the controller is put into Removing Mode.

Channels

The following table summarises the channels available for the LHC5031 DIN Mount Multiple Actuator Controller for Floor Heating.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch
Switch 3 switch_binary3 switch_binary Switch Switch
Switch 4 switch_binary4 switch_binary Switch Switch
Switch 5 switch_binary5 switch_binary Switch Switch
Switch 6 switch_binary6 switch_binary Switch Switch
Switch 7 switch_binary7 switch_binary Switch Switch
Switch 8 switch_binary8 switch_binary Switch Switch
Switch 9 switch_binary9 switch_binary Switch Switch
Switch 10 switch_binary10 switch_binary Switch Switch
Input (temperature) 1 sensor_temperature11 sensor_temperature Temperature Number
Input (temperature) 2 sensor_temperature12 sensor_temperature Temperature Number
Input (temperature) 3 sensor_temperature13 sensor_temperature Temperature Number
Input (temperature) 4 sensor_temperature14 sensor_temperature Temperature Number

Input (temperature) 1

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Input (temperature) 2

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Input (temperature) 3

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Input (temperature) 4

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the LHC5031 DIN Mount Multiple Actuator Controller for Floor Heating. Detailed information on each parameter can be found below.

Parameter Description
1: Status LED Configuration of the status LED
2: Status LED brightness level Configure the percentage of light in the status LED, when the LED is turned on.
3: Thermistor type connected to input 1 This parameter decides which kind of thermistor is connected to the input
4: Thermistor type connected to input 2 This parameter decides which kind of thermistor is connected to the input
5: Thermistor type connected to input 3 This parameter decides which kind of thermistor is connected to the input
6: Thermistor type connected to input 4 This parameter decides which kind of thermistor is connected to the input
7: Input 1 calibration -4.0 to 4.0 degree Celsius
8: Input 2 calibration -4.0 to 4.0 degree Celsius
9: Input 3 calibration -4.0 to 4.0 degree Celsius
10: Input 4 calibration -4.0 to 4.0 degree Celsius
11: Input 1 report interval Time interval between consecutive temperature reports
12: Input 2 report interval Time interval between consecutive temperature reports
13: Input 3 report intervals Time interval between consecutive temperature reports
14: Input 4 report interval Time interval between consecutive temperature reports
1: Group 1 Lifeline
2: Group 2 Analogue inputs
3: Group 3  
4: Group 4  
5: Group 5  

1: Status LED

Configuration of the status LED

Overview

0 = LED turned OFF, 1 = LED turned ON, 2 = LED flashing at 1 second intervals, 3 = LED flashing at 0.5 second intervals

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options LED turned OFF (0)      
  LED turned ON (1)      
  LED flashing at 1 sec interval (2)      
  LED flashing at 1/2 sec interval (3)      

2: Status LED brightness level

Configure the percentage of light in the status LED, when the LED is turned on.

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 100
Default Value 50

3: Thermistor type connected to input 1

This parameter decides which kind of thermistor is connected to the input

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options No thermistor, input is disabled (0)      
  10K NTC (Part number: TT02-10KC3-93D-3000R-TPH) (1)      

4: Thermistor type connected to input 2

This parameter decides which kind of thermistor is connected to the input

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options No thermistor, input is disabled (0)      
  10K NTC (Part number: TT02-10KC3-93D-3000R-TPH) (1)      

5: Thermistor type connected to input 3

This parameter decides which kind of thermistor is connected to the input

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options No thermistor, input is disabled (0)      
  10K NTC (Part number: TT02-10KC3-93D-3000R-TPH) (1)      

6: Thermistor type connected to input 4

This parameter decides which kind of thermistor is connected to the input

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options No thermistor, input is disabled (0)      
  10K NTC (Part number: TT02-10KC3-93D-3000R-TPH) (1)      

7: Input 1 calibration

-4.0 to 4.0 degree Celsius

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range -40 to 40
Default Value 0

8: Input 2 calibration

-4.0 to 4.0 degree Celsius

Property Value
Configuration ID config_8_1
Data Type INTEGER
Range -40 to 40
Default Value 0

9: Input 3 calibration

-4.0 to 4.0 degree Celsius

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range -40 to 40
Default Value 0

10: Input 4 calibration

-4.0 to 4.0 degree Celsius

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range -40 to 40
Default Value 0

11: Input 1 report interval

Time interval between consecutive temperature reports

Overview

Time interval between consecutive temperature reports. Temperature reports can also be sent as a result of polling.

Property Value
Configuration ID config_11_2
Data Type INTEGER
Range 0 to 8640
Default Value 6

12: Input 2 report interval

Time interval between consecutive temperature reports

Overview

Time interval between consecutive temperature reports. Temperature reports can also be sent as a result of polling.

Property Value
Configuration ID config_12_2
Data Type INTEGER
Range 0 to 8640
Default Value 6

13: Input 3 report intervals

Time interval between consecutive temperature reports

Overview

Time interval between consecutive temperature reports. Temperature reports can also be sent as a result of polling.

Property Value
Configuration ID config_13_2
Data Type INTEGER
Range 0 to 8640
Default Value 6

14: Input 4 report interval

Time interval between consecutive temperature reports

Overview

Time interval between consecutive temperature reports. Temperature reports can also be sent as a result of polling.

Property Value
Configuration ID config_14_2
Data Type INTEGER
Range 0 to 8640
Default Value 6

1: Group 1

Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Analogue inputs

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Group 4

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Group 5

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.