The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

MH-S311H Touch Panel Switch (Single) High inrush current

This describes the Z-Wave device MH-S311H, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_mhs311_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

MH-S311H product image

The MH-S311H supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

Touch Panel Switch is a wall switch with built-in Z-Wave module. It supports basic command class,multi channel command class and multi channel association command class, which can control all associated devices synchronously. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.

Inclusion Information

Press and hold any key on the panel for 8 seconds. If inclusion is successful, all INDICATION LEDs on the panel will turn green, and all switches will turn on.

Exclusion Information

Press and hold any key on the panel for 8 seconds. If the exclusion is successful, all INDICATION LEDs on the panel will turn orange, and all switches will turn off. The exclusion will delete all association data.

Wakeup Information

Same as inclusion

Channels

The following table summarises the channels available for the MH-S311H -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Scene Number scene_number   Number
Scene Number scene_number   Number
Switch 1 switch_binary1 Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the MH-S311H. Detailed information on each parameter can be found in the sections below.

Param Name Description
4 LED Backlit brightness level 0x00 LED disabled 0x01~0x0A Min level-Max level >0x0A same level as 0x0A
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 4: LED Backlit brightness level

0x00 LED disabled 0x01~0x0A Min level-Max level >0x0A same level as 0x0A

Values in the range 0 to 10 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MH-S311H supports 2 association groups.

Group 1: Switch Button Group 1

This group supports 5 nodes.

Group 2: All Status Reports

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V2| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| |

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_ASSOCIATION_V2  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.