The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

5082xx Battery Powered Wall Controller MOVE

This describes the Z-Wave device 5082xx, manufactured by Merten with the thing type UID of merten_5082xx_00_000.

The 5082xx does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the 5082xx -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the 5082xx. Detailed information on each parameter can be found in the sections below.

Param Name Description
4 Switching single-surface  
44 Doorbell function  
52 LOWER shutter as long as button is pressed Direction of movement changes after each switching process
54 Move shutter single-surface  
55 RAISE shutter as long as button is pressed  

Parameter 4: Switching single-surface

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 44: Doorbell function

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_44_1 and is of type INTEGER.

Parameter 52: LOWER shutter as long as button is pressed

Direction of movement changes after each switching process

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_52_1 and is of type INTEGER.

Parameter 54: Move shutter single-surface

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_54_1 and is of type INTEGER.

Parameter 55: RAISE shutter as long as button is pressed

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_55_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 5082xx supports 1 association group.

Group 1: Button

This group supports 12 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.