50x5xx Roller shutter push-button

This describes the Z-Wave device 50x5xx, manufactured by Merten with the thing type UID of merten_50x5xx_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

The 50x5xx supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

Inclusion Information

Program (transmits Node info frame)

Triple click on operating surface. Used for
include/exclude the device by the primary

Exclusion Information

Reset to the factory settings; exclude

Triple click on operating surface. Used for
include/exclude the device by the primary

Channels

The following table summarises the channels available for the 50x5xx -:

Channel Channel Id Category Item Type
Dimmer switch_dimmer DimmableLight Dimmer
Sensor (luminance) sensor_luminance Temperature Number
Dimmer 1 switch_dimmer1 DimmableLight Dimmer
Sensor (luminance) 1 sensor_luminance1 Temperature Number
Dimmer 2 switch_dimmer2 DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Sensor (luminance)

Indicates the current light reading.

The sensor_luminance channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Dimmer 1

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel supports the Dimmer item and is in the DimmableLight category.

Sensor (luminance) 1

Indicates the current light reading.

The sensor_luminance1 channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Dimmer 2

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer2 channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the 50x5xx. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 Switching/dimming/shutters  
4 Switching single-surface  
176 Break (motor protection) Changeover delay (motor protection) Input (0 - 255) * 0.1 s
177 Travel time UP, Byte 1 Input 1 (0 - 255)
178 Travel time UP, Byte 2 Input 2 (0 - 255)
179 Travel time DOWN, Byte 1 Input 1 (0 - 255)
180 Travel time DOWN, Byte 2 Input 2 (0 - 255)

Parameter 0: Switching/dimming/shutters

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 4: Switching single-surface

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 176: Break (motor protection)

Changeover delay (motor protection) Input (0 - 255) * 0.1 s

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_176_1 and is of type INTEGER.

Parameter 177: Travel time UP, Byte 1

Input 1 (0 - 255) Raising time
(256 * Input 1 + input 2) * 0.1 s Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_177_1 and is of type INTEGER.

Parameter 178: Travel time UP, Byte 2

Input 2 (0 - 255) Raising time
(256 * Input 1 + input 2) * 0.1 s Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_178_1 and is of type INTEGER.

Parameter 179: Travel time DOWN, Byte 1

Input 1 (0 - 255) Lowering time
(256 * Input 1 + input 2) * 0.1 s Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_179_1 and is of type INTEGER.

Parameter 180: Travel time DOWN, Byte 2

Input 2 (0 - 255) Lowering time
(256 * Input 1 + input 2) * 0.1 s Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_180_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 50x5xx supports 1 association group.

Group 1: Other device to be switched

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V1| | | COMMAND_CLASS_BASIC_WINDOW_COVERING_V1| Linked to BASIC| | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_PROTECTION_V2| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_SENSOR_CONFIGURATION_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V1| | | COMMAND_CLASS_BASIC_WINDOW_COVERING_V1| Linked to BASIC| | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_PROTECTION_V2| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_SENSOR_CONFIGURATION_V1| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_MULTILEVEL_V1  
COMMAND_CLASS_BASIC_WINDOW_COVERING_V1 Linked to BASIC
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_PROTECTION_V2  
COMMAND_CLASS_VERSION_V1  