506219 Battery Powered Wall Controller

This describes the Z-Wave device 506219, manufactured by Merten with the thing type UID of merten_506219_00_000.

Battery Powered Wall Controller

Overview

Single-surface push-button:

Top button: Association Group = 1 Parameter no. = 0

Bottom button: Association Group = 2 Parameter no. = 1

Dual-surface push-button:

Left top button: Association Group = 1 Parameter no. = 0

Left bottom button: Association Group = 2 Parameter no. = 1

Right top button: Association Group = 3 Parameter no. = 2

Right bottom button: Association Group = 4 Parameter no. = 3

Transmit “Node info frame”

Triple click on operating surface Wait until the red LED D goes out. Used to identify, associate and configure the device

Inclusion Information

Triple click on operating surface LED flashes approx. 6 seconds. Used for include/exclude the device by the primary

Channels

The following table summarises the channels available for the 506219 Battery Powered Wall Controller.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the 506219 Battery Powered Wall Controller. Detailed information on each parameter can be found below.

Parameter Description
0: Switching/dimming/shutters dual-surface:  
4: Switching single-surface  
44: Doorbell function  
52: LOWER shutter as long as button is pressed  
54: Move shutter single-surface direction of movement changes after each switching process
55: RAISE shutter as long as button is pressed  
60: Retrieve/save scene  
1: Left top button  
2: Left bottom button  
3: Right top button  
4: Right bottom button  

0: Switching/dimming/shutters dual-surface:

Property Value
Configuration ID config_0_1
Data Type INTEGER
Range 0 to 127
Default Value 0

4: Switching single-surface

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 127
Default Value 0

44: Doorbell function

Property Value
Configuration ID config_44_1
Data Type INTEGER
Range 0 to 127
Default Value 0

52: LOWER shutter as long as button is pressed

Property Value
Configuration ID config_52_1
Data Type INTEGER
Range 0 to 127
Default Value 0

54: Move shutter single-surface

direction of movement changes after each switching process

Property Value
Configuration ID config_54_1
Data Type INTEGER
Range 0 to 127
Default Value 0

55: RAISE shutter as long as button is pressed

Property Value
Configuration ID config_55_1
Data Type INTEGER
Range 0 to 127
Default Value 0

60: Retrieve/save scene

Property Value
Configuration ID config_60_1
Data Type INTEGER
Range 0 to 127
Default Value 0

1: Left top button

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Left bottom button

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Right top button

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Right bottom button

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.