50x5xx Roller shutter push-button

This describes the Z-Wave device 50x5xx, manufactured by Merten with the thing type UID of merten_50x5xx_00_000.

Roller shutter push-button

Inclusion Information

Program (transmits Node info frame)

Triple click on operating surface. Used for
include/exclude the device by the primary  

Exclusion Information

Reset to the factory settings; exclude  

Triple click on operating surface. Used for
include/exclude the device by the primary  

Channels

The following table summarises the channels available for the 50x5xx Roller shutter push-button.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Dimmer 1 switch_dimmer1 switch_dimmer DimmableLight Dimmer
Sensor (luminance) 1 sensor_luminance1 sensor_luminance Temperature Number
Dimmer 2 switch_dimmer2 switch_dimmer DimmableLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Dimmer 1

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Dimmer 2

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the 50x5xx Roller shutter push-button. Detailed information on each parameter can be found below.

Parameter Description
0: Switching/dimming/shutters  
4: Switching single-surface  
176: Break (motor protection) Changeover delay (motor protection) Input (0 - 255) * 0.1 s
177: Travel time UP, Byte 1 Input 1 (0 - 255)
178: Travel time UP, Byte 2 Input 2 (0 - 255)
179: Travel time DOWN, Byte 1 Input 1 (0 - 255)
180: Travel time DOWN, Byte 2 Input 2 (0 - 255)
1: Other device to be switched  

0: Switching/dimming/shutters

Property Value
Configuration ID config_0_1
Data Type INTEGER
Range 0 to 127
Default Value 0

4: Switching single-surface

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 127
Default Value 0

176: Break (motor protection)

Changeover delay (motor protection) Input (0 - 255) * 0.1 s

Property Value
Configuration ID config_176_1
Data Type INTEGER
Range 0 to 127
Default Value 0

177: Travel time UP, Byte 1

Input 1 (0 - 255)

Overview

Raising time
(256 * Input 1 + input 2) * 0.1 s  

Property Value
Configuration ID config_177_1
Data Type INTEGER
Range 0 to 127
Default Value 0

178: Travel time UP, Byte 2

Input 2 (0 - 255)

Overview

Raising time
(256 * Input 1 + input 2) * 0.1 s  

Property Value
Configuration ID config_178_1
Data Type INTEGER
Range 0 to 127
Default Value 0

179: Travel time DOWN, Byte 1

Input 1 (0 - 255)

Overview

Lowering time
(256 * Input 1 + input 2) * 0.1 s  

Property Value
Configuration ID config_179_1
Data Type INTEGER
Range 0 to 127
Default Value 0

180: Travel time DOWN, Byte 2

Input 2 (0 - 255)

Overview

Lowering time
(256 * Input 1 + input 2) * 0.1 s  

Property Value
Configuration ID config_180_1
Data Type INTEGER
Range 0 to 127
Default Value 0

1: Other device to be switched

Overview
Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.