MSP-3-1-X1 Z-Wave Plus Micro Smart Plug ON/OFF

This describes the Z-Wave device MSP-3-1-X1, manufactured by ID-RF with the thing type UID of nodon_msp31x1_00_000.

Z-Wave Plus Micro Smart Plug ON/OFF

Channels

The following table summarises the channels available for the MSP-3-1-X1 Z-Wave Plus Micro Smart Plug ON/OFF.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Reset Meter meter_reset meter_reset Energy Switch
Alarm (power) alarm_power alarm_power Door Switch
Alarm (system) alarm_system alarm_system   Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the MSP-3-1-X1 Z-Wave Plus Micro Smart Plug ON/OFF. Detailed information on each parameter can be found below.

Parameter Description
1: Default State Status after a power outage or after being plugged
3: Follow State Allows to enable or disable Group 2 & Group 3
4: Always On Forces the Micro Smart Plug status to be ON
21: Power Auto-Sending Report Power report for changes of x % W
22: Overload Report Switch off Micro Smart Plug in case the power is above x W
23: Energy Auto-Sending Report Auto energy report if value changes of x Wh
24: Metering Heartbeat Reporting intervall for power and energy to lifeline.
25: Power High Threshold Defines the High Threshold value in W.
26: Power Low Threshold Defines the Low Threshold value in W.
27: Power Threshold Action Defines actions if the power Low/High Threshold are reached.
1: Lifetime Report Information to Main Controller.
2: Follow State Send status if local button is used to associated devices.
3: Follow Comp State Send status if local button is used to associated devices.
4: Metering High Threshold Send ON/OFF command to associated devices if threshold reached
5: Metering Low Threshold Send ON/OFF command to associated devices if threshold reached
6: Metering - Report Report metering to devices in this group.

1: Default State

Status after a power outage or after being plugged

Overview

This parameter defines the status of the Micro Smart Plug after a power outage or after being plugged

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 2
Options OFF (0)      
  ON (1)      
  Status before power outage (2)      

3: Follow State

Allows to enable or disable Group 2 & Group 3

Overview

This parameter allows to enable or disable Group 2 & Group 3

The value may be the sum of available values. For example, if you want to enable Group 2 & 3, the parameter value is 1+2=3

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 3
Options Group 2 & Group 3 disable (0)      
  Group 2 enable (1)      
  Group 3 enable (2)      
  Group 2 & Group 3 enable (3)      

4: Always On

Forces the Micro Smart Plug status to be ON

Overview

This parameter forces the Micro Smart Plug status to be ON. While enable it is not possible to switch OFF the plug (local or wireless).

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 0
Options Always ON disable (0)      
  Always ON enable (1)      

21: Power Auto-Sending Report

Power report for changes of x % W

Overview

This parameter will send a power report automatically if  the power value  changes of x % W (Watt) compared to the last report.

Property Value      
Configuration ID config_21_1      
Data Type INTEGER      
Range 0 to 100   Default Value 10
Options Power Auto-Polling Report Disable (0)      
  Power Auto-Polling Report Enable if 10% (10)      
  Power Auto-Polling Report Enable if 20 % (20)      
  Power Auto-Polling Report Enable if 30 % (30)      
  Power Auto-Polling Report Enable if 40 % (40)      
  Power Auto-Polling Report Enable if 50 % (50)      
  Power Auto-Polling Report Enable if 60 % (60)      
  Power Auto-Polling Report Enable if 70 % (70)      
  Power Auto-Polling Report Enable if 80 % (80)      
  Power Auto-Polling Report Enable if 90 % (90)      
  Power Auto-Polling Report Enable if 100% (100)      

22: Overload Report

Switch off Micro Smart Plug in case the power is above x W

Overview

This parameter will switch off the Micro Smart Plug in case the power is above  x W (Watt) and send an alarm to the primary controller. This parameter has the highest execution priority between all the metering configurations for security reason.

Property Value      
Configuration ID config_22_2      
Data Type INTEGER      
Range 0 to 2000   Default Value 2000
Options Overload Report Disable (Not Recommended) (0)      
  Overload Report enable with a upper limit of 50 W (50)      
  Overload Report enable with a upper limit of 100 W (100)      
  Overload Report enable with a upper limit of 150 W (150)      
  Overload Report enable with a upper limit of 200 W (200)      
  Overload Report enable with a upper limit of 250 W (250)      
  Overload Report enable with a upper limit of 500 W (500)      
  Overload Report enable with a upper limit of 1000 W (1000)      
  Overload Report enable with a upper limit of 1500 W (1500)      
  Overload Report enable with a upper limit of 2000 W (2000)      

23: Energy Auto-Sending Report

Auto energy report if value changes of x Wh

Overview

This parameter will send a new energy report automatically if the energy value changes of x Wh (Watt-hour) compared to the last report.

Property Value      
Configuration ID config_23_2      
Data Type INTEGER      
Range 0 to 65535   Default Value 1000
Options Energy Auto-Polling Report Disable (0)      
  Energy Auto-Polling Report enable if 1000 Wh variation (1000)      
  Energy Auto-Polling Report enable if 2000 Wh variation (2000)      
  Energy Auto-Polling Report enable if 3000 Wh variation (3000)      
  Energy Auto-Polling Report enable if 4000 Wh variation (4000)      
  Energy Auto-Polling Report enable if 5000 Wh variation (5000)      
  Energy Auto-Polling Report enable if 10.000 Wh variation (10000)      
  Energy Auto-Polling Report enable if 20.000 Wh variation (20000)      
  Energy Auto-Polling Report enable if 30.000 Wh variation (30000)      
  Energy Auto-Polling Report enable if 40.000 Wh variation (40000)      
  Energy Auto-Polling Report enable if 50.000 Wh variation (50000)      
  Energy Auto-Polling Report enable if 60.000 Wh variation (60000)      
  Energy Auto-Polling Report enable if 65.535 Wh variation (65535)      

24: Metering Heartbeat

Reporting intervall for power and energy to lifeline.

Overview

Whatever other metering reports, this parameter will send one power and one energy report to the lifeline every x s (Seconds).

Property Value      
Configuration ID config_24_2      
Data Type INTEGER      
Range 0 to 65535   Default Value 3600
Options Metering Pulse disable (0)      
  Metering Pulse enable and send report every hour (3600)      
  Metering Pulse enable and send report every 6 hours (21600)      
  Metering Pulse enable and send report every 12 hours (43200)      

25: Power High Threshold

Defines the High Threshold value in W.

Overview

This parameter defines the High Threshold power value.

Property Value      
Configuration ID config_25_2      
Data Type INTEGER      
Range 0 to 65535   Default Value 20
Options Power High Threshold disable (0)      
  Power High Threshold enable with the value from 10 W (10)      
  Power High Threshold enable with the value from 20 W (20)      
  Power High Threshold enable with the value from 30 W (30)      
  Power High Threshold enable with the value from 40 W (40)      
  Power High Threshold enable with the value from 50 W (50)      
  Power High Threshold enable with the value from 100 W (100)      
  Power High Threshold enable with the value from 200 W (200)      
  Power High Threshold enable with the value from 300 W (300)      
  Power High Threshold enable with the value from 400 W (400)      
  Power High Threshold enable with the value from 500 W (500)      
  Power High Threshold enable with the value from 1000 W (1000)      
  Power High Threshold enable with the value from 1500 W (1500)      
  Power High Threshold enable with the value from 2000 W (2000)      

26: Power Low Threshold

Defines the Low Threshold value in W.

Overview

This parameter defines the Low Threshold power value.

Property Value      
Configuration ID config_26_2      
Data Type INTEGER      
Range 0 to 65535   Default Value 5
Options Power Low Threshold disable (0)      
  Power Low Threshold enable with the value from 5 W (5)      
  Power Low Threshold enable with the value from 10 W (10)      
  Power Low Threshold enable with the value from 20 W (20)      
  Power Low Threshold enable with the value from 30 W (30)      
  Power Low Threshold enable with the value from 40 W (40)      
  Power Low Threshold enable with the value from 50 W (50)      
  Power Low Threshold enable with the value from 100 W (100)      
  Power Low Threshold enable with the value from 200 W (200)      
  Power Low Threshold enable with the value from 300 W (300)      
  Power Low Threshold enable with the value from 400 W (400)      
  Power Low Threshold enable with the value from 500 W (500)      
  Power Low Threshold enable with the value from 1000 W (1000)      
  Power Low Threshold enable with the value from 1500 W (1500)      
  Power Low Threshold enable with the value from 2000 W (2000)      

27: Power Threshold Action

Defines actions if the power Low/High Threshold are reached.

Overview

This parameter will define the Micro Smart Plug actions if the power Low and High Threshold are reached.

The value may be the sum of available values. For example, if you want:

  • Power High Threshold Action is enable and sent ON to Group 4 (3)
  • Power Low Threshold Action is enable and sent OFF to Group 5 (4)

the parameter value must be 3+4=7.

Property Value      
Configuration ID config_27_1      
Data Type INTEGER   Default Value 7
Options Power Threshold Action is disable. (0)      
  Power High Group 4 OFF (1)      
  Power High Group 4 ON (3)      
  Power Low Group 5 OFF (4)      
  Power High Group 4 OFF & Power Low Group 5 OFF (5)      
  Power High Group 4 ON & Power Low Group 5 OFF (7)      
  Power High Group 5 ON (12)      
  Power High Group 4 OFF & Power Low Gourp 5 ON (13)      
  Power High Group 4 ON & Power Low Group 5 ON (15)      

1: Lifetime

Report Information to Main Controller.

Overview

This group is generally used to report information of the Micro Smart Plug to the Main Controller of the network.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Follow State

Send status if local button is used to associated devices.

Overview

When the Micro Smart Plug is switched ON (respectively OFF) using the local button, it will send ON (respectively OFF) command to the associated devices. No command is sent if the Micro Smart Plug is switched ON or OFF wirelessly.

This group is configurable through the parameter 3.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Follow Comp State

Send status if local button is used to associated devices.

Overview

When the Micro Smart Plug is switched ON (respectively OFF) using the local button, it will send OFF (respectively ON) command to the associated devices. No command is sent if the Micro Smart Plug is switched ON or OFF wirelessly.

This group is configurable through the parameter 3.

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Metering High Threshold

Send ON/OFF command to associated devices if threshold reached

Overview

When the Micro Smart Plug reaches over the high threshold of power defined by the configuration parameter, it will send OFF or ON command to the associated devices.

This group is configurable through the parameter 25 and 27.

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Metering Low Threshold

Send ON/OFF command to associated devices if threshold reached

Overview

When the Micro Smart Plug reaches below the low threshold of power defined by the configuration parameter, it will send OFF or ON command to the associated devices.

This group is configurable through the parameters 26 and 27.

Property Value
Configuration ID group_5
Data Type TEXT
Range to

6: Metering - Report

Report metering to devices in this group.

Overview

All the meter reports and notifications triggered by Metering parameters will be reported to the devices present in this group.

This group is configurable through the parameters 21, 22, 23 and 24.

Property Value
Configuration ID group_6
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.