Oomi Plug Oomi Plug is a low-cost Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool.

This describes the Z-Wave device Oomi Plug, manufactured by Fantem with the thing type UID of oomi_oomiplug_00_000.

Oomi Plug is a low-cost Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool.

Channels

The following table summarises the channels available for the Oomi Plug Oomi Plug is a low-cost Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool..

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Meter Reset meter_reset meter_reset Energy Switch
Color Control color_color color_color   Color
Color Temperature color_temperature color_temperature ColorLight Dimmer
Clock Time Offset time_offset time_offset Temperature Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the Oomi Plug Oomi Plug is a low-cost Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool.. Detailed information on each parameter can be found below.

Parameter Description
3: Current overload protection enable Current overload protection enable
20: Output load after re-power Configure the output load status after re‐power
80: Enable send to associated devices Enable to send notifications to Group 1
81: Configure LED state Configure the state of the LED
83: Color in night light mode  
83: Blue night light color value Blue night light color value
83: Green night light color value Green night light color value
83: Red night light color value Configure the RGB value when it is in Night light mode
84: Color in energy mode  
84: Green brightness in energy mode (%) Green brightness in energy mode (%)
84: Yellow brightness in energy mode (%) Yellow brightness in energy mode (%)
84: Red brightness in energy mode (%) Red brightness in energy mode (%)
90: Enable items 91 and 92 Enables/disables parameter 91 and 92
91: Wattage Threshold minimum change in wattage to trigger
92: Wattage Percent Change minimum change in wattage percent
101: Values to send to group 1 Which reports need to send in Report group 1
102: Values to send to group 2 Which reports need to send in Report group 2
103: Values to send to group 3 Which reports need to send in Report group 3
111: Time interval for sending to group 1 Group 1 automatic update interval
112: Time interval for sending to group 2 Group 2 automatic update interval
113: Time interval for sending to group 3 Group 3 automatic update interval
252: Configuration Locked Enable/disable Configuration Locked (0 =disable, 1 = enable).
33: RGB LED color testing Set the RGB LED color value for testing.
100: Set 101‐103 to default. Set 101‐103 to default.
110: Set 111‐113 to default. Set 111‐113 to default.
255: RESET Reset the device to defaults
1: Group 1 load notification type (lifeline)
2: Group 2 forwarding basic set (retransmit)

3: Current overload protection enable

Current overload protection enable

Overview

Current Overload Protection. Load will be closed when the Current overrun (US: 15.5A, other country: 16.2A) and the time more than 2 minutes (0=disabled, 1=enabled).

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options disabled (0)      
  enabled (1)      

20: Output load after re-power

Configure the output load status after re‐power

Overview

Configure the output load status after re-power on
(0=last status, 1=always on, 2=always off)

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 0
Options last status (0)      
  always on (1)      
  always off (2)      

80: Enable send to associated devices

Enable to send notifications to Group 1

Overview

Enable to send notifications to associated devices (Group 1) when the state of Micro Switch’s load changed (0=nothing, 1=hail CC, 2=basic CC report).

Property Value      
Configuration ID config_80_1      
Data Type INTEGER   Default Value 0
Options nothing (0)      
  hail CC (1)      
  basic CC report (2)      

81: Configure LED state

Configure the state of the LED

Overview

Configure the state of LED when it is in 3 modes below:

  • 0= The LED will follow the status (on/off) of its load (Energy mode).
  • 1= When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action (momentary indicate mode).
  • 2= Night light mode.
Property Value      
Configuration ID config_81_1      
Data Type INTEGER   Default Value 0
Options LED follows load (0)      
  LED follows load for 5 seconds (1)      
  Night light mode (2)      

83: Color in night light mode

Property Value
Configuration ID config_83_3
Data Type INTEGER
Range 0 to 16777215
Default Value 0

83: Blue night light color value

Blue night light color value

Overview

Value for parameter 83, night light blue color

Property Value
Configuration ID config_83_3_000000FF
Data Type INTEGER
Range 0 to 255
Default Value 221

83: Green night light color value

Green night light color value

Overview

Green color value for parameter 83, night light mode.

Property Value
Configuration ID config_83_3_0000FF00
Data Type INTEGER
Range 0 to 255
Default Value 160

83: Red night light color value

Configure the RGB value when it is in Night light mode

Overview

Configure the RGB value when it is in Night light mode.
Value1: Red color value
Value2: Green color value
Value3: Blue color value

defaults:

Value1=0xDD
Value2=0xA0
Value3=0xDD

Property Value
Configuration ID config_83_3_00FF0000
Data Type INTEGER
Range 0 to 255
Default Value 221

84: Color in energy mode

Property Value
Configuration ID config_84_3
Data Type INTEGER
Range 0 to 16777215
Default Value 0

84: Green brightness in energy mode (%)

Green brightness in energy mode (%)

Overview

Configure the brightness level of RGB LED (0%-100%) when
it is in Energy Mode/momentary indicate mode.
Value1: green color value.
Value2: yellow color value.
Value3: red color value.

Property Value
Configuration ID config_84_3_000000FF
Data Type INTEGER
Range 0 to 100
Default Value 50

84: Yellow brightness in energy mode (%)

Yellow brightness in energy mode (%)

Property Value
Configuration ID config_84_3_0000FF00
Data Type INTEGER
Range 0 to 100
Default Value 50

84: Red brightness in energy mode (%)

Red brightness in energy mode (%)

Property Value
Configuration ID config_84_3_00FF0000
Data Type INTEGER
Range 0 to 100
Default Value 50

90: Enable items 91 and 92

Enables/disables parameter 91 and 92

Overview

Enables/disables parameter 91 and 92 below (1=enabled, 0=disabled).

Property Value      
Configuration ID config_90_1      
Data Type INTEGER   Default Value 1
Options disabled (0)      
  enabled (1)      

91: Wattage Threshold

minimum change in wattage to trigger

Overview

The value here represents minimum change in wattage (in
terms of wattage) for a REPORT to be sent (Valid values 0-
60000).

Property Value
Configuration ID config_91_2
Data Type INTEGER
Range 0 to 60000
Default Value 25

92: Wattage Percent Change

minimum change in wattage percent

Overview

The value here represents minimum change in wattage
percent (in terms of percentage) for a REPORT to be sent
(Valid values 0-100).

Property Value
Configuration ID config_92_1
Data Type INTEGER
Range 0 to 100
Default Value 5

101: Values to send to group 1

Which reports need to send in Report group 1

Property Value      
Configuration ID config_101_4      
Data Type INTEGER   Default Value 4
Options Nothing (0)      
  Voltage (1)      
  Current (2)      
  Wattage (4)      
  kWh (8)      
  All Values (15)      

102: Values to send to group 2

Which reports need to send in Report group 2

Property Value      
Configuration ID config_102_4      
Data Type INTEGER   Default Value 8
Options Nothing (0)      
  Voltage (1)      
  Current (2)      
  Wattage (4)      
  kWh (8)      
  All Values (15)      

103: Values to send to group 3

Which reports need to send in Report group 3

Property Value      
Configuration ID config_103_4      
Data Type INTEGER   Default Value 0
Options Nothing (0)      
  Voltage (1)      
  Current (2)      
  Wattage (4)      
  kWh (8)      
  All Values (15)      

111: Time interval for sending to group 1

Group 1 automatic update interval

Overview

The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF).

Default value is 3

Note: Only up to 0x7fffffff is currently supported

Property Value
Configuration ID config_111_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 3

112: Time interval for sending to group 2

Group 2 automatic update interval

Overview

The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF).

Default value is 600

Note: Only up to 0x7fffffff is currently supported

Property Value
Configuration ID config_112_4
Data Type INTEGER
Range 1 to 2147483647
Default Value 600

113: Time interval for sending to group 3

Group 3 automatic update interval

Overview

The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF).

Default value is 600

Note: Only up to 0x7fffffff is currently supported

Property Value
Configuration ID config_113_4
Data Type INTEGER
Range 600 to 1
Default Value 2147483647

252: Configuration Locked

Enable/disable Configuration Locked (0 =disable, 1 = enable).

Overview

Enable/disable Configuration Locked (0 =disable, 1 =enable).

Property Value      
Configuration ID config_252_1      
Data Type INTEGER   Default Value 0
Options disabled (0)      
  enabled (1)      

33: RGB LED color testing

Set the RGB LED color value for testing.

Overview

Value1: Reserved

Value2: Red value

Value3: Green value

Value4: Blue value

Property Value
Configuration ID config_33_4_wo
Data Type INTEGER
Range 0 to 4294967295
Default Value 0

100: Set 101‐103 to default.

Set 101‐103 to default.

Property Value      
Configuration ID config_100_1_wo      
Data Type INTEGER   Default Value 0
Options False (0)      
  True (1)      

110: Set 111‐113 to default.

Set 111‐113 to default.

Property Value      
Configuration ID config_110_1_wo      
Data Type INTEGER   Default Value 0
Options False (0)      
  True (1)      

255: RESET

Reset the device to defaults

Overview

Reset configuration set up to default setting.

Property Value
Configuration ID config_255_1_wo
Data Type INTEGER
Range to
Default Value 0

1: Group 1

load notification type (lifeline)

Overview

When the state of Smart Switch (turn on/off the load ) is changed:

  1. Set Configuration parameter 80 to 0 Reserved (Default).
  2. Set Configuration parameter 80 to 1 Send Hail CC.
  3. Set Configuration parameter 80 to 2: Send the Basic Report.
Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

forwarding basic set (retransmit)

Overview

Forward the Basic Set, Switch Binary Set to associated nodes in Group 2 when the Smart Switch receives the Basic Set, Switch Binary Set commands from main controller.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.