PAN03 In Wall Micromodule Single Switch

This describes the Z-Wave device PAN03, manufactured by Philio Technology Corp with the thing type UID of philio_pan03_00_000.

PAN03 product image

The PAN03 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the PAN03 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Electric meter (watts) meter_watts Energy Number
Electric meter (power factor) meter_powerfactor Energy Number
Electric meter (volts) meter_voltage Energy Number
Electric meter (amps) meter_current Energy Number
Electric meter (kWh) meter_kwh Energy Number
Alarm alarm_general Door Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the PAN03. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Watt Meter Report Period Watt Meter Report Period
2 KWH Meter Report Period KWH Meter Report Period (6*10min=1 hour)
3 Threshold of current for Load caution Threshold of current for Load caution (1100*0.01A = 11A)
4 Threshold of KWh for Load caution Threshold of KWh for Load caution
5 Restore switch state mode Restore switch state mode
6 Manual On/Off mode Manual On/Off mode
7 LED indication mode LED indication mode
8 Auto off timer Auto off timer
9 RF off command mode RF off command mode
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Watt Meter Report Period

Watt Meter Report Period WATT METER REPORT PERIOD:

If the setting is configured for 1hour (set value =720), the Micromodule Single Switch Max.Load: 11A will report its instant power consumption every 1 hour to Group1 node. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: KWH Meter Report Period

KWH Meter Report Period (6*10min=1 hour) KWH METER REPORT PERIOD:

If the setting is configured for 1hour (set value =6), the Micromodule Single Switch Max.Load: 11A will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Threshold of current for Load caution

Threshold of current for Load caution (1100*0.01A = 11A) THRESHOLD OF CURRENT FOR LOAD CAUTION:

This is a warning when the current of load over the preset threshold value, if the setting value is 1100, when the load current of Relay1 over this value, Micromodule Single Switch Max.Load: 11A will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1100, and the default value is 1100. Values in the range 10 to 1100 may be set.

The manufacturer defined default value is 1100.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Threshold of KWh for Load caution

Threshold of KWh for Load caution THRESHOLD OF KWH FOR LOAD CAUTION

This is a warning when the KWh of load over the preset threshold value, if the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, Micromodule Single Switch Max.Load: 11A will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh Values in the range 10 to 10000 may be set.

The manufacturer defined default value is 10000.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Restore switch state mode

Restore switch state mode RESTORE SWITCH STATE MODE:

Whenever the AC power return from lost, Micromodule Single Switch Max.Load: 11A will restore the switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE. The following option values may be configured -:

Value Description
0 Switch off
1 Last switch state
2 Switch on

The manufacturer defined default value is 1 (Last switch state).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Manual On/Off mode

Manual On/Off mode MANUAL ON/OFF MODE:

The On/Off function of S1, S2 and learn switch can be disabled or enabled by this parameter, default value is Enable. But the learning operation won’t be affected. When manual On/Off function is disabled, the RF command can only switch On but not Off. This is useful function for keeping the device in switch on state The following option values may be configured -:

Value Description
0 Disable manual On/Off
1 Enable manual On/Off

The manufacturer defined default value is 0 (Disable manual On/Off).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: LED indication mode

LED indication mode

The following option values may be configured -:

Value Description
1 Show switch state
2 Show night mode
2 One flash mode

The manufacturer defined default value is 1 (Show switch state).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Auto off timer

Auto off timer AUTO OFF TIMER:

Whenever Micromodule Single Switch Max.Load: 11A switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0. Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: RF off command mode

RF off command mode RF OFF COMMAND MODE:

Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. The following option values may be configured -:

Value Description
0 Switch off
1 Ignore
2 Switch toggle
3 Switch on

The manufacturer defined default value is 0 (Switch off).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN03 supports 1 association group.

Group 1: Group 1

the Switch will report its latest status to Z-Wave Controller This group supports 1 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_METER_V3  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_PROTECTION_V2  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  
COMMAND_CLASS_SECURITY_V0  