The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

PAN06 In Wall Dual Relay(1 Way) Switch Module 2x 1.5kW

This describes the Z-Wave device PAN06, manufactured by Philio Technology Corp with the thing type UID of philio_pan06_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

PAN06 product image

The PAN06 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the PAN06 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Alarm alarm_general Door Switch
Switch 1 switch_binary1 Switch Switch
Switch 2 switch_binary2 Switch Switch
Switch 3 switch_binary3 Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Switch 3

Switch the power on and off.

The switch_binary3 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the PAN06. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Selected endpoint  
2 Switch mode Change the external switch mode
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Selected endpoint

If Controller not using Multi_Channel command class to access the endpoint of PAN06, you may configure the endpoint value to react the Basic Command Class The following option values may be configured -:

Value Description
1 Relay 1 + 2
2 Relay 1
3 Relay 2

The manufacturer defined default value is 1 (Relay 1 + 2).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Switch mode

Change the external switch mode

The following option values may be configured -:

Value Description
1 Edge mode
2 Pulse mode
3 Edge-Toggle mode

The manufacturer defined default value is 1 (Edge mode).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN06 supports 3 association groups.

Group 1: Relay 1 + 2

This group supports 1 nodes.

Group 2: Relay 1

This group supports 1 nodes.

Group 3: Relay 2

This group supports 1 nodes.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC|

Endpoint 2

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC|

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.