ZIP-PAB01 Zipato Micromodule Energy Meter

This describes the Z-Wave device ZIP-PAB01, manufactured by Philio Technology Corp with the thing type UID of philio_pab01_00_000.

Zipato Micromodule Energy Meter

Channels

The following table summarises the channels available for the ZIP-PAB01 Zipato Micromodule Energy Meter.

Channel Channel Id Channel Type UID Category Item Type
Intensty meter 0 (amps) meter_current meter_current Energy Number
Power factor 0 meter_powerfactor meter_powerfactor Energy Number
Power meter 0 (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Line voltage (volts) meter_voltage meter_voltage Energy Number
Intensity meter 1 (amps) meter_current1 meter_current Energy Number
Power factor meter 1 meter_powerfactor1 meter_powerfactor Energy Number
Power meter 1 (watts) meter_watts1 meter_watts Energy Number
Energy meter 1 (kWh) meter_kwh1 meter_kwh Energy Number
Line voltage (volts) meter_voltage1 meter_voltage Energy Number
Intensity meter 2 (amps) meter_current2 meter_current Energy Number
power factor 2 meter_powerfactor2 meter_powerfactor Energy Number
Power meter 2 (watts) meter_watts2 meter_watts Energy Number
Energy meter 2 (kWh) meter_kwh2 meter_kwh Energy Number
Line voltage 2 (volts) meter_voltage2 meter_voltage Energy Number
Intensity meter 3 (amps) meter_current3 meter_current Energy Number
Power factor 3 meter_powerfactor3 meter_powerfactor Energy Number
Power meter 3 (watts) meter_watts3 meter_watts Energy Number
Energy meter 3 (kWh) meter_kwh3 meter_kwh Energy Number
Voltage 3 (volts) meter_voltage3 meter_voltage Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZIP-PAB01 Zipato Micromodule Energy Meter. Detailed information on each parameter can be found below.

Parameter Description
1: Power meter report period Power meter report period, in 5 seconds unit. 720 -> 1 hour
2: Energy meter report period The accumulated power consumption report period
3: Selected default endpoint 1 => CT1 and CT2, 2 => CT1, 3 => CT2
1: CT1 and CT2 Sum of CT1 and CT2
2: CT1 Data from CT1
3: CT2 Data from CT2

1: Power meter report period

Power meter report period, in 5 seconds unit. 720 -> 1 hour

Overview

If the setting is configured for 1 hour (set value 720), the module will report its instant power consumption every 1 hour to the node of the corresponding group. The maximum interval to report its instant power consumption is 45h (5s * 32767 / 3600 = 45h)

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 1 to 32767
Default Value 720

2: Energy meter report period

The accumulated power consumption report period

Overview

If the setting is configured for 1 hour (set value 720), the module will report its accumulated power consumption every 1 hour to the node of the corresponding group. The maximum interval to report its accumulated power consumption is 45h (5s * 32767 / 3600 = 45h)

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 32767
Default Value 720

3: Selected default endpoint

1 => CT1 and CT2, 2 => CT1, 3 => CT2

Overview

If Controller does not use Multi Channel command class to access the endpoint of the module, you may configure the endpoint that will react to the Basic Command Class, Binary Switch command class or Meter command class V3.

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 3
Default Value 1

1: CT1 and CT2

Sum of CT1 and CT2

Overview

Sum of :

  • Instant power consumption from CT1 and CT2 (W)
  • Accumulated power consumption from CT1 and CT2 (kWh)
Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: CT1

Data from CT1

Overview
  • Instant power consumption from CT1 (W)
  • Accumulated power consumption from CT1 (kWh)
Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: CT2

Data from CT2

Overview
  1. Instant power consumption from CT2 (W)
  2. Accumulated power consumption from CT2 (kWh)
Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.