PAN03 In Wall Micromodule Single Switch

This describes the Z-Wave device PAN03, manufactured by Philio Technology Corp with the thing type UID of philio_pan03_00_000.

In Wall Micromodule Single Switch

Channels

The following table summarises the channels available for the PAN03 In Wall Micromodule Single Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the PAN03 In Wall Micromodule Single Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Watt Meter Report Period Watt Meter Report Period
2: KWH Meter Report Period KWH Meter Report Period (6*10min=1 hour)
3: Threshold of current for Load caution Threshold of current for Load caution (1100*0.01A = 11A)
4: Threshold of KWh for Load caution Threshold of KWh for Load caution
5: Restore switch state mode Restore switch state mode
6: Manual On/Off mode Manual On/Off mode
7: LED indication mode LED indication mode
8: Auto off timer Auto off timer
9: RF off command mode RF off command mode
1: Group 1 the Switch will report its latest status to Z-Wave Controller

1: Watt Meter Report Period

Watt Meter Report Period

Overview

WATT METER REPORT PERIOD:

If the setting is configured for 1hour (set value =720), the Micromodule Single Switch Max.Load: 11A will report its instant power consumption every 1 hour to Group1 node. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 1 to 32767
Default Value 720

2: KWH Meter Report Period

KWH Meter Report Period (6*10min=1 hour)

Overview

KWH METER REPORT PERIOD:

If the setting is configured for 1hour (set value =6), the Micromodule Single Switch Max.Load: 11A will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 32767
Default Value 6

3: Threshold of current for Load caution

Threshold of current for Load caution (1100*0.01A = 11A)

Overview

THRESHOLD OF CURRENT FOR LOAD CAUTION:

This is a warning when the current of load over the preset threshold value, if the setting value is 1100, when the load current of Relay1 over this value, Micromodule Single Switch Max.Load: 11A will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1100, and the default value is 1100.

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 10 to 1100
Default Value 1100

4: Threshold of KWh for Load caution

Threshold of KWh for Load caution

Overview

THRESHOLD OF KWH FOR LOAD CAUTION

This is a warning when the KWh of load over the preset threshold value, if the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, Micromodule Single Switch Max.Load: 11A will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 10 to 10000
Default Value 10000

5: Restore switch state mode

Restore switch state mode

Overview

RESTORE SWITCH STATE MODE:

Whenever the AC power return from lost, Micromodule Single Switch Max.Load: 11A will restore the switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Switch off (0)      
  Last switch state (1)      
  Switch on (2)      

6: Manual On/Off mode

Manual On/Off mode

Overview

MANUAL ON/OFF MODE:

The On/Off function of S1, S2 and learn switch can be disabled or enabled by this parameter, default value is Enable. But the learning operation won’t be affected. When manual On/Off function is disabled, the RF command can only switch On but not Off. This is useful function for keeping the device in switch on state

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 0
Options Disable manual On/Off (0)      
  Enable manual On/Off (1)      

7: LED indication mode

LED indication mode

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options Show switch state (1)      
  Show night mode (2)      
  One flash mode (2)      

8: Auto off timer

Auto off timer

Overview

AUTO OFF TIMER:

Whenever Micromodule Single Switch Max.Load: 11A switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0.

Property Value
Configuration ID config_8_2
Data Type INTEGER
Range 0 to 32767
Default Value 0

9: RF off command mode

RF off command mode

Overview

RF OFF COMMAND MODE:

Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. 

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 0
Options Switch off (0)      
  Ignore (1)      
  Switch toggle (2)      
  Switch on (3)      

1: Group 1

the Switch will report its latest status to Z-Wave Controller

Overview

Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.