PAN04 In Wall Dual Relay(1 Way) Switch Module 2x 1.5kW with power meter

This describes the Z-Wave device PAN04, manufactured by Philio Technology Corp with the thing type UID of philio_pan04_00_000.

In Wall Dual Relay(1 Way) Switch Module 2x 1.5kW with power meter

Channels

The following table summarises the channels available for the PAN04 In Wall Dual Relay(1 Way) Switch Module 2x 1.5kW with power meter.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Alarm alarm_general alarm_general Door Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (power factor) 1 meter_powerfactor1 meter_powerfactor Energy Number
Electric meter (amps) 1 meter_current1 meter_current Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (volts) 1 meter_voltage1 meter_voltage Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (power factor) 2 meter_powerfactor2 meter_powerfactor Energy Number
Electric meter (amps) 2 meter_current2 meter_current Energy Number
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (volts) 2 meter_voltage2 meter_voltage Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Switch 3 switch_binary3 switch_binary Switch Switch
Electric meter (power factor) 3 meter_powerfactor3 meter_powerfactor Energy Number
Electric meter (amps) 3 meter_current3 meter_current Energy Number
Electric meter (kWh) 3 meter_kwh3 meter_kwh Energy Number
Electric meter (volts) 3 meter_voltage3 meter_voltage Energy Number
Electric meter (watts) 3 meter_watts3 meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the PAN04 In Wall Dual Relay(1 Way) Switch Module 2x 1.5kW with power meter. Detailed information on each parameter can be found below.

Parameter Description
1: W meter report period Period for reporting W meter
2: kWh meter report period Period for reporting kWh meter
3: Selected endpoint Which endpoint is addressed by the BASIC command class
4: Switch mode Change the external switch mode
5: Threshold of Watt for Load Caution If threshold of wattage is reached, a meter report will be generated
6: Threshold of kWh for Load Caution If threshold of kWh is reached, a Meter Report will be generated
7: Restore switch state mode Restore switch state mode
8: Auto Off Timer Auto Off Timer
9: RF off command mode RF off command mode
10: Endpoint 3 Endpoint 3
1: Relay 1 + 2  
2: Relay 1  
3: Relay 2  

1: W meter report period

Period for reporting W meter

Overview

If the setting is configured for 1 hour (value = 720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. Unit: 5 seconds

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 65535
Default Value 720

2: kWh meter report period

Period for reporting kWh meter

Overview

If the setting is configured for 1 hour (value = 6), the device will report its total power consumption every 1 hour to Z-Wave Controller. 

Unit: 10 minutes

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 6

3: Selected endpoint

Which endpoint is addressed by the BASIC command class

Overview

If the Controller is not using Multi_Channel command class to access the endpoint of PAN04, you may configure the endpoint value to react the Basic Command Class

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 1
Options Relay 1 (1)      
  Relay 2 (2)      
  Relay 1 + 2 (3)      

4: Switch mode

Change the external switch mode

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options Edge mode (1)      
  Pulse mode (2)      
  Edge-Toggle mode (3)      

5: Threshold of Watt for Load Caution

If threshold of wattage is reached, a meter report will be generated

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 0 to 65535
Default Value 750

6: Threshold of kWh for Load Caution

If threshold of kWh is reached, a Meter Report will be generated

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 65535
Default Value 10000

7: Restore switch state mode

Restore switch state mode

Overview

Restores the switch state setting in case the device was disconnected from the power source.

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options Switch Off (0)      
  Last State (1)      
  Switch On (2)      

8: Auto Off Timer

Auto Off Timer

Overview

Whenever the device switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch off automatically.

Property Value
Configuration ID config_8_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

9: RF off command mode

RF off command mode

Overview

Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands.

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 1
Options Switch Off (0)      
  Ignore (1)      
  Switch Toggle (2)      
  Switch On (3)      

10: Endpoint 3

Endpoint 3

Overview

Multi-Channel Command is a good way to control relay1 and relay2 of PAN04 individually. The endpoint3 of PAN04 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class.

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 1
Options Exists (1)      
  Doesn't Exist (2)      

1: Relay 1 + 2

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Relay 1

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Relay 2

Property Value
Configuration ID group_3
Data Type TEXT
Range to