PAN08-1a Roller shutter controller

This describes the Z-Wave device PAN08-1a, manufactured by Philio Technology Corp with the thing type UID of philio_pan081a_00_000.

Roller shutter controller

Overview

The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter
connected to its terminals using radio waves, controllers and a push button directly
connected to this Roller Controller.
This in-wall Roller Shutter Controller is a transceiver which is a Z-Wave PlusTM
enabled device and is fully compatible with any Z-WaveTM enabled network. Slim
design let the Controller can easily hide itself into the wall box and that will be good
for the house decoration.
The new smart relay calibration technology can reduce the inrush current caused by
the load and let the module work perfectly with many kind of Roller Shutter.
This in-wall Roller Shutter Controller is able to detect position of the Shutter by using
the patterned power measuring method, so it can be remote controlled not only fully
up or down , but also can be adjusted to ex. 30% or 50%. And when manual
controlled by push button, the controller also can memorize the position and send the
new shutter position to its controller (ex. IP-Gateway).

Inclusion Information

In the front casing, there is an include button with LED indicator below which is used
to carry out inclusion, exclusion, reset or association. When first power is applied, its
LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies
that it has not been assigned a node ID and start auto inclusion.

The function of auto inclusion will be executed as long as the PAN08 does not have
Node ID and just connect the PAN08 to main power.

Note: Auto inclusion timeout is 2 minute during which the node information of
explorer frame will be emitted once every several seconds.

Exclusion Information

 Put your Z-Wave controller into
exclusion mode by following the
instructions provided by the
controller manufacturer.

 Pressing Include button three times
within 2 seconds will enter exclusion
mode.

Wakeup Information

Device is not battery operated, hence no wakeup procedure.

Channels

The following table summarises the channels available for the PAN08-1a Roller shutter controller.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number   Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Alarm alarm_general alarm_general Door Switch

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the PAN08-1a Roller shutter controller. Detailed information on each parameter can be found below.

Parameter Description
1: Watt meter report interval (5s) Interval (x5 seconds) to send out watt meter report
2: KWH Meter Report Interval (10min) Interval (x10 minutes) to send out KWH Meter Report
3: Threshold for Load Caution (10mA) Threshold (x0.01A) of current for Load Caution
4: Threshold of KWh for Load Caution  
5: External SwitchType Sets the type of an external switch
6: Level report mode Sets the way the controller reports the shutter level
1: Blind Control  

1: Watt meter report interval (5s)

Interval (x5 seconds) to send out watt meter report

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 1 to 32767
Default Value 720

2: KWH Meter Report Interval (10min)

Interval (x10 minutes) to send out KWH Meter Report

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 32767
Default Value 6

3: Threshold for Load Caution (10mA)

Threshold (x0.01A) of current for Load Caution

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 1 to 1100
Default Value 500

4: Threshold of KWh for Load Caution

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 1 to 10000
Default Value 10000

5: External SwitchType

Sets the type of an external switch

Overview

1: One Push button

2: Two push bittons

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 1 to 2
Default Value 2

6: Level report mode

Sets the way the controller reports the shutter level

Overview

1: Report destination level in 5s

2: Report 10 percent level while running

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 1 to 2
Default Value 2

1: Blind Control

Property Value
Configuration ID group_1
Data Type TEXT
Range to