PAN08 Relay Insert for Blind Control

This describes the Z-Wave device PAN08, manufactured by Philio Technology Corp with the thing type UID of philio_pan08_00_000.

Relay Insert for Blind Control

Channels

The following table summarises the channels available for the PAN08 Relay Insert for Blind Control.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Blinds Control blinds_control blinds_control Blinds Rollershutter
Scene Number scene_number scene_number   Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Alarm alarm_general alarm_general Door Switch

Blinds Control

Invert control

Invert the blinds control

Property Value      
Configuration ID config_invert_control      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Invert percentage value

Invert the blinds percentage value

Property Value      
Configuration ID config_invert_percent      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Step duration

Sets the dim rate speed
Values from 1 to 127 are defined in seconds, while values from 128 to 254 are defined in minutes.

Property Value      
Configuration ID config_duration      
Data Type INTEGER      
Range 1 to 254   Default Value 255
Options Device Default (255)      
  Change Instantly (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the PAN08 Relay Insert for Blind Control. Detailed information on each parameter can be found below.

Parameter Description
1: Watt meter report interval (5s) Interval (x5 seconds) to send out watt meter report
2: KWH Meter Report Interval (10min) Interval (x10 minutes) to send out KWH Meter Report
3: Threshold for Load Caution (10mA) Threshold (x0.01A) of current for Load Caution
4: Threshold of KWh for Load Caution  
1: Blind Control  

1: Watt meter report interval (5s)

Interval (x5 seconds) to send out watt meter report

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 1 to 32767
Default Value 720

2: KWH Meter Report Interval (10min)

Interval (x10 minutes) to send out KWH Meter Report

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 32767
Default Value 6

3: Threshold for Load Caution (10mA)

Threshold (x0.01A) of current for Load Caution

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 1 to 1100
Default Value 1100

4: Threshold of KWh for Load Caution

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 1 to 10000
Default Value 10000

1: Blind Control

Property Value
Configuration ID group_1
Data Type TEXT
Range to