PAN11 Smart Energy Plug In Switch

This describes the Z-Wave device PAN11, manufactured by Philio Technology Corp with the thing type UID of philio_pan11_00_000.

Smart Energy Plug In Switch

Channels

The following table summarises the channels available for the PAN11 Smart Energy Plug In Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Reset the total power consumption meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the PAN11 Smart Energy Plug In Switch. Detailed information on each parameter can be found below.

Parameter Description
1: W meter report period Set automatic W meter reporting interval
2: kWh meter report period Set automatic kWh meter reporting interval.
3: Threshold of Watt for load caution Set threshold of wattage meter value for load caution .
4: Threshold of kWh for Load Caution If threshold of kWh is reached, a Meter Report will be generated
5: Restore switch state mode  
6: Mode of switch Off function  
7: LED indication mode  
8: Auto Off Timer Auto off timer. 0 will disable the auto off function.
9: RF Off command mode  
1: Reports  

1: W meter report period

Set automatic W meter reporting interval

Overview

If the setting is configured for 1hour (set value =720), the PAN11 will report its instant power consumption every 1 hour to Group1 node. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 32767
Default Value 720

2: kWh meter report period

Set automatic kWh meter reporting interval.

Overview

If the setting is configured for 1hour (set value =6), the PAN11 will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 32767
Default Value 6

3: Threshold of Watt for load caution

Set threshold of wattage meter value for load caution .

Overview

This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, PAN11 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300. 

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 10 to 1300
Default Value 1300

4: Threshold of kWh for Load Caution

If threshold of kWh is reached, a Meter Report will be generated

Overview

Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting.

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 1 to 10000
Default Value 10000

5: Restore switch state mode

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Switch Off (0)      
  Last State (1)      
  Switch On (2)      

6: Mode of switch Off function

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 1
Options SWITCH OFF commands received are ignored. (0)      
  SWITCH OFF commands received are honored. (1)      

7: LED indication mode

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options The LED follows the state of the switch. (1)      
  LED off with load ON (2)      
  One flash mode (3)      

8: Auto Off Timer

Auto off timer. 0 will disable the auto off function.

Property Value
Configuration ID config_8_2
Data Type INTEGER
Range 0 to 255
Default Value 0

9: RF Off command mode

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 0
Options Switch Off (0)      
  Ignore (1)      
  Switch Toggle (2)      
  Switch On (3)      

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to