PAT02-B Z-Wave room sensor

This describes the Z-Wave device PAT02-B, manufactured by Philio Technology Corp with the thing type UID of philio_pat02b_00_000.

Z-Wave room sensor

Channels

The following table summarises the channels available for the PAT02-B Z-Wave room sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the PAT02-B Z-Wave room sensor. Detailed information on each parameter can be found below.

Parameter Description
5: Operation Mode set Operation Mode using bit to control
7: Customer Function Customer Function switch using bit control
10: Auto Report Battery Time The interval time for auto reporting the battery level.
13: Auto Report Temperature Time The interval time for auto reporting the temperature state.
14: Auto Report Humidity Time The interval time for auto reporting the humidity state.
20: Auto Report Tick Interval The interval time for auto report each tick.
21: Temperature Differential Report The temperature differential to report.
23: Humidity Differential Report The humidity differential to report.
1: Reports  
2: Light Control  

5: Operation Mode

set Operation Mode using bit to control

Overview

set Operation Mode using bit to control

  • Bit 0: Reserve
  • Bit 1: Reserve
  • Bit 2: Reserve
  • Bit 3: Setting temperature scale

    • 0: Fahrenheit
    • 1: Celsius
  • Bit 4: Reserve
  • Bit 5: Reserve
  • Bit 6: Reserve
  • Bit 7: Reserve
Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 0 to 255
Default Value 0

7: Customer Function

Customer Function switch using bit control

Overview

Customer Function switch using bit control

  • Bit 0: Reserve
  • Bit 1: Reserve
  • Bit 2: Reserve
  • Bit 3: not applicable for this device variant, set to 0
  • Bit 4: Notification Type

    • 0: Using Notification Report
    • 1: Using Sensor Binary Report
  • Bit 5: Disable Multi CC in auto report

    • 0: Enable
    • 1: Disable
  • Bit 6: not applicable for this device variant, set to 0
  • Bit 7: Reserve
Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 0 to 255
Default Value 0

10: Auto Report Battery Time

The interval time for auto reporting the battery level.

Overview

The interval time for auto reporting the battery level.

  • 0 = Turn off auto report battery.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 1 to 127
Default Value 12

13: Auto Report Temperature Time

The interval time for auto reporting the temperature state.

Overview

The interval time for auto reporting the temperature state.

  • 0 = Turn off auto report temperature.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Property Value
Configuration ID config_13_1
Data Type INTEGER
Range 1 to 127
Default Value 12

14: Auto Report Humidity Time

The interval time for auto reporting the humidity state.

Overview

The interval time for auto reporting the humidity state.

  • 0 = Turn off auto report.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20.
Property Value
Configuration ID config_14_1
Data Type INTEGER
Range 0 to 127
Default Value 0

20: Auto Report Tick Interval

The interval time for auto report each tick.

Overview

The interval time for auto report each tick. Units of one minute. Setting configuration will affect configuration no. 10, 13, 14 and 15.

  • Caution1: Setting to 0 means turn off all auto report function.
  • Caution2: The value is unsigned byte.
Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 255
Default Value 30

21: Temperature Differential Report

The temperature differential to report.

Overview

The temperature differential to report.

  • The unit is Fahrenheit.
  • Enable this function the device will detect every 10 seconds.
Property Value
Configuration ID config_21_1
Data Type INTEGER
Range 0 to 127
Default Value 0

23: Humidity Differential Report

The humidity differential to report.

Overview

The humidity differential to report.

  • The unit is percentage.
  • Enable this function the device will detect every 10 seconds.
Property Value
Configuration ID config_23_1
Data Type INTEGER
Range 0 to 60
Default Value 5

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Light Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to