PAT02-C Flood Sensor

This describes the Z-Wave device PAT02-C, manufactured by Philio Technology Corp with the thing type UID of philio_pat02c_00_000.

Flood Sensor

Channels

The following table summarises the channels available for the PAT02-C Flood Sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Alarm (flood) alarm_flood alarm_flood Door Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the PAT02-C Flood Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Set OFF Level Setting the BASIC command value
2: Basic Set ON Level Setting the BASIC command value
5: Operation Mode Operation mode. Using bit to control.
7: Customer Function Parameter to set the sensor functions
10: Auto Report Battery Time The interval time for auto report the battery level.
15: Auto Report Flood Time The interval time for auto report the flood state.
20: Auto Report Tick Interval The interval time for auto reporting each tick.
1: Reports  
2: Light Control  

1: Basic Set OFF Level

Setting the BASIC command value

Overview
  • Setting the BASIC command value

    • When the flood trigger off(0x00), send the BASIC CC to the group 2.
Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 0

2: Basic Set ON Level

Setting the BASIC command value

Overview
  • Setting the BASIC command value

    • When the flood trigger on(0xFF), send the BASIC CC to the group 2.  
Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 255
Default Value 255

5: Operation Mode

Operation mode. Using bit to control.

Overview

Operation mode. Using bit to control.

  • Bit0: Disable the Flood function.
  • Bit1: Reserve.
  • Bit2: Reserve.
  • Bit3: not applicable for this device variant, set to 0
  • Bit4: Reserve.
  • Bit5: not applicable for this device variant, set to 1
  • Bit6: Reserve.
  • Bit7: Reserve.
Property Value      
Configuration ID config_5_1      
Data Type INTEGER      
Range 0 to 255   Default Value 0
Options Flood function is enabled (32)      
  Flood function is disabled (33)      

7: Customer Function

Parameter to set the sensor functions

Overview

Customer Function switch using bit control

  • Bit 0: Reserve
  • Bit 1: Reserve
  • Bit 2: Reserve
  • Bit 3: Disable send out BASI OFF after flood event cleared

    • 0: Enable
    • 1: Disable
  • Bit 4: Notification Type

    • 0: Using Notification Report
    • 1: Using Sensor Binary Report
  • Bit 5: Disable Multi CC in auto report

    • 0: Enable
    • 1: Disable
  • Bit 6: Disable to report Battery state when the device triggered

    • 0: Enable
    • 1: Disable
  • Bit 7: Reserve
Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 0 to 255
Default Value 0

10: Auto Report Battery Time

The interval time for auto report the battery level.

Overview

The interval time for auto report the battery level.

0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20.

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 127
Default Value 12

15: Auto Report Flood Time

The interval time for auto report the flood state.

Overview

The interval time for auto report the flood state.

0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20.

Property Value
Configuration ID config_15_1
Data Type INTEGER
Range 0 to 127
Default Value 12

20: Auto Report Tick Interval

The interval time for auto reporting each tick.

Overview

The interval time for auto report each tick.

Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.

Units of one minute.

Caution1: Setting to 0 means turn off all auto report function.

Caution2: The value is unsigned byte

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 255
Default Value 30

1: Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Light Control

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.